Tridonic 28000660 – LCA 75W 900-1800mA one4all lp PRE – Intelligent Voltage Guard
28000660
Tridonic 28000660 LCA 75W 900-1800mA one4all lp PRE
- NEW: lumDATA (DALI-2 part ext. 251, 252 and 253)
- Dimmable built-in constant current LED driver
- Dimming range 1 to 100 %
£41.90
Ex.VAT Inc.VAT£50.28
Description
Tridonic 28000660 – LCA 75W 900-1800mA one4all lp PRE
28000660 Description
NEW: lumDATA (DALI-2 part ext. 251, 252 and 253)
Dimmable built-in constant current LED driver
Dimming range 1 to 100 %
For luminaires of protection class I and protection class II
Output current adjustable between 900 – 1,800 mA
Max. output power 75 W
Up to 91 % efficiency
Power input on stand-by < 0.15 W
Nominal lifetime up to 100,000 h
28000660 Housing properties
Low profile metal casing with white cover
Type of protection IP20
28000660 Interfaces
one4all (DALI-2 DT 6, DSI, switchDIM, corridorFUNCTION)
ready2mains (configuration and dimming via mains)
Terminal blocks: 0° push terminals
28000660 Functions
Adjustable output current in 1-mA-steps (DALI, ready2mains, I-SELECT 2)
Fulfills DALI-2 parts: 251 (Luminaire data), 252 (Energy reporting) and 253 (Diagnostics & Maintenance)
Constant light output function (CLO)
Power-up fading at AC
Configurable via ready2mains
Switch off the driver with fade2zero
Service monitor to log certain events
Protective features (overtemperature, short-circuit, overload, no-load, input voltage range, reduced surge amplification)
Intelligent Voltage Guard (overvoltage and undervoltage monitoring)
Suitable for emergency escape lighting systems acc. to EN 50172
28000660 Benefits
Flexible configuration via companionSUITE
Application-oriented operating window for maximum compatibility
Best energy savings due to low stand-by losses and high efficiency
Flexible configuration via DALI, ready2mains and I-SELECT 2
Reliability proven by lifetime up to 100,000 h and 5 years guarantee (conditions at https://www.tridonic.com/en/int/services/manufacturer-guarantee-conditions)
Typical applications for the 28000660
For linear/area lighting in office applications
28000660 Common Data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
DC voltage range 176 – 280 V
Mains frequency 0 / 50 / 60 Hz
Overvoltage protection 320 V AC, 48 h
Typ. current (at 230 V, 50 Hz, full load) (1)(2) 228 – 363 mA
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) 50 – 71 mA
Leakage current (at 230 V, 50 Hz, full load) (1)(2) < 0.55 mA
Typ. input current in no-load operation 33 mA
In-rush current (peak / duration) 34 A / 193 µs
Max. input power 83 W
Typ. power consumption on stand-by (3) < 0.15 W
Typ. input power in no-load operation 0.41 W
Typ. efficiency (at 230 V, 50 Hz, full load) (2) 91 %
λ (at 230 V, 50 Hz, full load) (1) 0.98
THD (at 230 V, 50 Hz, full load) (1) < 8.2 %
Starting time (at 230 V, 50 Hz, full load) (4) < 0.6 s
Starting time (DC mode) (4) < 0.3 s
Switchover time (AC/DC) (5) < 0.3 s
Turn off time (at 230 V, 50 Hz, full load) < 0.004 s
Output current tolerance (1)(6) ± 3 %
Max. output current peak (non-repetitive) ≤ output current + 40 %
Output LF current ripple (< 120 Hz) ± 5 %
Output P_ST_LM (at full load) ≤ 1
Output SVM (at full load) ≤ 0.4
Max. output voltage (U-OUT) 60 V
Dimming range 1 – 100 %
Mains surge capability (between L – N) 1 kV
Mains surge capability (between L/N – PE) 2 kV
Surge voltage at output side (against PE) < 0.5 kV
Type of protection IP20
Length 360 mm
Width 30 mm
Height 21 mm
Lifetime up to 100000 h
28000660 Wiring
28000660 Wiring type and cross section
Solid wire with a cross section of 0.5 – 1.5 mm². Strip 8 – 9 mm of insulation from the cables to ensure perfect operation of terminals.
28000660 Wiring guidelines
• Run the secondary lines separately from the mains connections and lines to achieve good EMC performance.
• The max. secondary cable length is 2 m (4 m circuit), this applies for LED output as well as for I-SELECT 2.
• For good EMC performance, keep the LED wiring as short as possible.
• Secondary switching is not permitted.
• The LED driver has no inverse-polarity protection on the secondary side.
Wrong polarity can damage LED modules with no inverse-polarity protection.
• Wrong wiring of the LED driver can lead to malfunction or irreparable damage.
• To avoid the damage of the Driver, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver,
etc.).
Earth connection
The earth connection is conducted as protection earth (PE). The LED driver can be earthed via earth terminal or metal housing. If the LED driver will be earthed, protection earth (PE) has to be used. There is no earth connection required for the functionality of the LED driver. Earth connection is recommended to improve following behaviour:
• Electromagnetic interferences (EMI)
• LED glowing at stand-by
• Transmission of mains transients to the LED output
In general it is recommended to earth the LED driver if the LED module is mounted on earthed luminaire parts respectively heat sinks and thereby representing a high capacity against earth.
Tridonic are a Zumtobel Group company, founded in 1956 in Dornbirn, Austria. For more than 60 years, they have been a driving force in the development of professional lighting solutions.
Today, Tridonic is a world-leading provider of lighting technology for professional applications, including office buildings, and retail outlets, hotels and restaurants, the education industry and outdoor lighting sectors.
In Tridonics’ extensive range of energy-efficient dimmable and non-dimmable LED drivers they offer the right products for every indoor and outdoor application – from cost-efficient LED drivers in proven Tridonic quality to premium products that give you maximum flexibility and convenience.
Tridonics’ dimmable LED drivers can be controlled with different analog and digital dimming signals. Tridonic basicDIM Wireless products allow wireless control without additional wiring.
Need to know more about Tridonic 28000660 – LCA 75W 900-1800mA one4all lp PRE – Intelligent Voltage Guard?
You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.