Tridonic 28000700 LC 25W 350–1050mA flexC SR EXC – Suitable For Emergency Escape Lighting Systems acc. to EN 50172
28000700
Tridonic 28000700 LC 25W 350–1050mA flexC SR EXC
The 28000700 is a 25W independent constant-current LED driver designed for flexible lighting applications.
£19.80
Ex.VAT Inc.VAT£23.76
Less Than 10 Available!
Description
Tridonic 28000700 LC 25W 350–1050mA flexC SR EXC
28000700 Description
Independent constant current LED driver
Adjustable output current between 350 and 1,050 mA via ready2mains Programmer or I-SELECT 2 plugs
Max. output power 25 W
Up to 86 % efficiency
Nominal lifetime up to 100,000 h
28000700 Housing properties
Casing: polycarbonate, white
Type of protection IP20
Strain relief with loop through function
Designed for independent use, for built-in use the 28000706 can be used
28000700 Interfaces
ready2mains (configuration via mains)
Terminal blocks: 0° / 45° push terminals (input / output)
28000700 Functions
Adjustable output current in 1-mA-steps (ready2mains, I-SELECT 2)
Protective features (overtemperature, short-circuit, overload, no-load, input voltage range)
Suitable for emergency escape lighting systems acc. to EN 50172
For cable cross-sections up to 2.5 mm²
28000700 Benefits
Application-oriented operating window for maximum compatibility
Best energy savings due to high efficiency
Flexible configuration via ready2mains and I-SELECT 2
No tools required for installation
Typical applications for the 28000700
For downlight, spotlight and decorative applications
28000700 Common Data
Ordering data LC 25W 350-1050mA flexC SR EXC 28000700
28000700 Technical data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
DC voltage range 176 – 280 V
Mains frequency 0 / 50 / 60 Hz
Overvoltage protection 320 V AC, 48 h
Typ. rated current (at 230 V, 50 Hz, full load) (1) 133 mA
Typ. current (220 V, 0 Hz, full load, 57 % dimming level) (1) 85 mA
Leakage current (at 230 V, 50 Hz, full load) (1) < 0.25 mA
Typ. input current in no-load operation 17 mA
In-rush current (peak / duration) 16 A / 229 µs
Max. input power 29.8 W
Typ. input power in no-load operation 0.5 W
Typ. efficiency (at 230 V, 50 Hz, full load) (1) 86 %
λ (at 230 V, 50 Hz, full load) 0.95
THD (at 230 V, 50 Hz, full load) < 10 %
Starting time (at 230 V, 50 Hz, full load) < 0.5 s
Starting time (DC mode) < 0.5 s
Switchover time (AC/DC) (2) < 0.2 s
Turn off time (at 230 V, 50 Hz, full load) < 0.05 s
Output current tolerance (3) ± 5 %
Max. output current peak (non-repetitive) ≤ output current + 35 %
Output LF current ripple (< 120 Hz) ± 5 %
Max. output voltage (U-OUT) 60 V
Mains surge capability (between L – N) 1 kV
Mains surge capability (between L/N – PE) 2 kV
Burst / surge peaks output side against PE < 500 kV
Type of protection IP20
Length 200 mm
Width 70 mm
Height 31 mm
Lifetime up to 100000 h
Guarantee 5 years
(1) Depending on the selected output current.
(2) Valid for immediate change of power supply type otherwise the starting time is valid.
(3) Output current is mean value.
28000700 Standards
EN 55015
EN 61000-3-2
EN 61000-3-3
EN 61347-1
EN 61347-2-13
EN 62384
EN 61547
According to EN 50172 for use in central battery systems
According to EN 60598-2-22 suitable for emergency lighting installations
Glow wire test
according to EN 61347-1 with increased temperature of 850 °C passed
28000700 Thermal details and lifetime
The LED driver is designed for a lifetime stated above under reference conditions and with a failure probability of less than 10 %.
The relation of tc to ta temperature depends also on the luminaire design.
If the measured tc temperature is approx. 5 K below tc max., ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request.
28000700 Installation / wiring
28000700 Wiring type and cross section
Mains supply wires
For wiring use stranded wire with ferrules or solid wire from 0.5–2.5 mm2.
Strip 10–11 mm of insulation from the cables to ensure perfect operation of the push terminals.
Use one wire for each terminal connector only.
Use each strain relief channel for one cable only
Secondary wires (LED module)
For wiring use stranded wire with ferrules or solid wire from 0.2–1.5 mm².
Strip 8.5–9.5 mm of insulation from the cables to ensure perfect operation of the push-wire terminals.
Use one wire for each terminal connector only.
Use each strain relief channel for one cable only.
Loose wiring

Fixing conditions
Dry, acidfree, oilfree, fatfree. It is not allowed to exceed the maximum ambient temperature (ta) stated on the device. Minimum distances stated below are recommendations and depend on the actual luminaire. Is not suitable for fixing in corner.
Device not suitable for covering with thermally insulating material according to IEC 60598-1 Ed.9
28000700 Wiring guidelines
• The cables should be run separately from the mains connections and mains cables to ensure good EMC conditions.
• The LED wiring should be kept as short as possible to ensure good EMC.
The max. secondary cable length is 2 m (4 m circuit).
• To comply with the EMC regulations run the secondary wires (LED module) in parallel.
• Secondary switching is not permitted.
• The 28000700 has no inverse-polarity protection on the secondary side.
Wrong polarity can damage LED modules with no inverse-polarity protection.
• Wrong wiring of the LED driver can lead to malfunction or irreparable damage.
• Through wiring of mains is for connecting additional LED driver only.
Max. permanent current of 15.5 A may not be exceeded.
• To avoid damage of the Driver, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver,
etc.).
Hot plug-in
Hot plug-in is not supported due to residual output voltage of > 0 V. When connecting an LED load, restart the device to activate the LED output. This can be done via mains reset.
Earth connection
The earth connection is conducted as protection earth (PE). If the LED driver will be earthed, protection earth (PE) has to be used. There is no earth connection required for the functionality of the LED driver.
Earth connection is recommended to improve following behaviour:
• Electromagnetic interferences (EMI)
• Transmission of mains transients to the LED output
In general it is recommended to earth the LED driver if the LED module is mounted on earthed luminaire parts respectively heat sinks and thereby representing a high capacity against earth.
Operating window
Make sure that the LED driver is operated within the given window under all operating conditions. Special attention needs to be paid at dimming and DC emergency operation as the forward voltage of the connected LED modules varies with the dimming level, due to the implemented amplitude dimming technology. Coming below the specified minimum output voltage of the LED driver may cause the device to shut-down. See chapter “6.7 DC emergency operation” for more information.
28000700 Interfaces / communication
Configuration input ready2mains (L, N)
The digital ready2mains protocol is modulated onto the mains signal which is wired to the mains terminal (L and N).
28000700 Functions
Function: adjustable current
The output current of the 28000700 can be adjusted in a certain range.
For adjustment there are two options available.
Option 1: I-SELECT 2
By inserting a suitable resistor or third party resistor into the I-SELECT 2 interface, the current value can be adjusted. The relationship between output current and resistor value can be found in the chapter “Accessories I-SELECT 2 Plugs”.
Please note that the resistor values for I-SELECT 2 are not compatible with I-SELECT (generation 1). Installation of an incorrect resistor may cause irreparable damage to the LED module(s).
Resistors for the main output current values can be ordered from Tridonic (see accessories).
Option 2: ready2mains
Adjustment is done by the ready2mains Programmer and the corresponding configuration software (see ready2mains documentation).
Current adjustment can only be done five times over ready2mains. To program the LED driver a connected load is necessary that is within the operating window of the LED driver.
The priority for current adjustment methods is I-SELECT 2 followed by ready2mains (lowest priority).
ready2mains – configuration
The ready2mains interface enables the configuration of the mostly used parameters via the mains wiring.
In the case of EXC LED driver, it is the LED output current as well as an optional lockbit to prevent any accidental configuration at a later stage.
The configuration is done via the ready2mains Programmer, either directly at the Programmer itself or via a respective software tool. For details on the configuration via ready2mains see the technical information of the Programmer and its tools.
Short-circuit behaviour
In case of a short-circuit at the LED output the LED output is switched off.
After restart of the LED driver the output will be activated again. The restart can be done via mains reset.
No-load operation
The LED driver will not be damaged in no-load operation. The output will be deactivated and is therefore free of voltage. If a LED load is connected the device has to be restarted before the output will be activated again.
Overload protection
If the maximum load is exceeded by a defined internal limit, the LED driver turns off the LED output.
After restart of the LED driver the output will be activated again. The restart can be done via mains reset.
Overtemperature protection
The LED driver is protected against temporary thermal overheating. If the temperature limit is exceeded the output current of the LED module(s) is reduced. The temperature protection is activated above tc max.
The activation temperature differs depending on the LED load. On DC operation this function is deactivated to fulfil emergency requirements.
DC emergency operation
The LED driver is designed to operate on DC voltage and pulsed DC voltage. For a reliable operation, make sure that also in DC emergency operation the LED driver is run within the specified conditions as stated in chapter
Miscellaneous
Insulation and electric strength testing of luminaires
Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production.
According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an insulation test with 500 V DC for one second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal.
The insulation resistance must be at least 2 MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted
Conditions of use and storage for the 28000700
Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %)
Storage temperature: -40 °C up to max. +80 °C
The devices have to be acclimatised to the specified temperature range (ta) before they can be operated
Maximum number of switching cycles
All LED driver are tested with 50,000 switching cycles. The actually achieved number of switching cycles is significantly higher.
Constant current (CC) LED drivers are specialized power supplies that maintain a fixed, consistent current output (measured in mA or A) to high-power LEDs, regardless of input voltage fluctuations or temperature changes. They automatically adjust voltage to prevent thermal runaway and ensure consistent brightness, making them essential for enhancing LED lifespan and efficiency.
Key Aspects of Constant Current LED Drivers:
Functionality: They prevent LEDs from drawing too much current, which can cause premature burn-out. They typically operate by adjusting voltage automatically within a specific range.
Best Use Cases: Ideal for powering high-power LEDs, COB (Chip on Board) LEDs, and LED arrays (e.g., in series). They are commonly used in downlights, architectural lighting, and display.
Wiring Method: Generally, LEDs must be wired in a series configuration for a constant current driver to operate correctly, ensuring each LED receives the same, consistent current.
Specifications: They are rated by a specific mA/A output and a corresponding voltage range (e.g., 350mA, 700mA, 1050mA).
Benefits: These drivers offer higher efficiency and better protection against thermal runaway compared to constant voltage drivers.
Key Differences: Constant Current (CC) vs. Constant Voltage (CV)
CC: Constant current, variable voltage. Best for raw, high-power LEDs.
CV: Constant voltage, variable current. Best for LED strips with built-in resistors.
Selecting a Constant Current Driver
Match the mA: The driver’s output current (mA) must match the requirements of the LED.
Check Wattage/Voltage: Ensure the total power required by the LED series does not exceed the driver’s maximum wattage.
Tridonic are a Zumtobel Group company, founded in 1956 in Dornbirn, Austria. For more than 60 years, they have been a driving force in the development of professional lighting solutions.
Today, Tridonic is a world-leading provider of lighting technology for professional applications, including office buildings, and retail outlets, hotels and restaurants, the education industry and outdoor lighting sectors.
In Tridonics’ extensive range of energy-efficient dimmable and non-dimmable LED drivers they offer the right products for every indoor and outdoor application – from cost-efficient LED drivers in proven Tridonic quality to premium products that give you maximum flexibility and convenience.
Tridonics’ dimmable LED drivers can be controlled with different analog and digital dimming signals. Tridonic basicDIM Wireless products allow wireless control without additional wiring.
Need to know more about Tridonic 28000700 LC 25W 350–1050mA flexC SR EXC – Suitable For Emergency Escape Lighting Systems acc. to EN 50172?
You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.