Tridonic 28002242 DLA G2 100mm 1000lm 840 SNC EM MOD – Complete ready2apply Solution
28002242
Tridonic 28002242 DLA G2 100mm 1000lm 840 SNC EM MOD
28002242 Description
LED replacement for downlight with compact fluorescent lamps
Complete ready2apply solution comprising module, driver, reflector and trim ring
£11.24
Ex.VAT Inc.VAT£13.49
Less Than 10 Available!
Description
Tridonic 28002242 DLA G2 100mm 1000lm 840 SNC EM MOD
28002242 Description
LED replacement for downlight with compact fluorescent lamps
Complete ready2apply solution comprising module, driver, reflector and trim ring
Ripple current 5 % and UGR19 (specific model only) makes office installation possible
Approved emergency solution with EM converterLED
Optional reflector solution with 60° and 90°
Nominal lifetime of 50,000 h (L70/B50)
28002242 Optical properties
Colour temperatures 3,000 and 4,000 K
Typ. luminous flux category: 1,000/2,000/3,000 lm
High colour rendering index CRI > 80
Small colour tolerance (MacAdam 4)
28002242 Mechanical properties
Fit for ceiling cutout 100, 150 and 200 mm
Tool-free assembly, simple as push and rotate
Spring clip pre-assembled
System solution
High system efficacy up to 111 lm/W
28002242 Common data
28002242 Technical aata
Beam characteristic 60° / 90° / 100°
Ambient temperature ta -20 … +40 °C
tc temperature (100 mm, 1000lm) 1 60 °C
tc temperature (150 mm, 1000lm) 1 55 °C
tc temperature (150 mm, 2000lm) 1 65 °C
tc temperature (200 mm, 2000lm) 1 60 °C
tc temperature (200 mm, 3000lm) 1 65 °C
ESD classification Severity level 2
Max. working voltage for insulation 60 V
Colour tolerance 4 SDCM
Risk group (IEC 62471) RG1
Type of protection IP20
Lumen maintenance L70B50 50,000 h
28002242 Standards
EN 62031
EN 62471
IEC 61000-4-2
IEC TR 62778: 2014
Glow wire test
according to EN 62031 with increased temperature of 850 °C passed.
Photometric code
Key for photometric code, e. g. 830 / 469
Insulation and electric strength testing of luminaires
Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production.
According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an insulation test with 500V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal.
The insulation resistance must be at least 2MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500V AC (or 1.414 x 1500V DC). To avoid damage to the electronic devices this test must not be conducted.
28002242 Thermal details
tp point, ambient temperature and lifetime
The temperature at tp reference point is crucial for the light output and lifetime of a LED product.
The operating temperature of a LED product is crucial for the light output, the product lifetime but also for the product safety.
The thermal limits can be checked at the tp/tc point. On page 11 the lumen maintenance is shown in relation to the temperature at tp. tp,rated shows the temperature at which the rated values are reached. tc shows the thermal limit for safety reason und must never be exceeded under normal conditions.
For DLA G2 SNC the tp temperature has to be complied in order to achieve an optimum between heat sink requirements, light output and lifetime.
Compliance with the maximum permissible reference temperature at the tp point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application.
The tc and tp temperature of LED modules from Tridonic are measured at the same reference point.
Assembly of DLA G2 SNC
Thermal behaviour
Operation only in non condensing environment.
Humidity during processing of the module should be between 30 to 70 %
28002242 Lifetime
Lifetime, lumen maintenance and failure rate
The light output of an LED module decreases over the lifetime, this is characterized with the L value. L70 means that the LED module will give 70 % of its initial luminous flux. This value is always related to the number of operation hours and therefore defines the lifetime of an LED module.
As the L value is a statistical value and the lumen maintenance may vary over the delivered LED modules. The B value defines the amount of modules which are below the specific L value, e.g. L70B10 means 10 % of the LED modules are below 70 % of the initial luminousflux, respectively 90 % will be above 70 % of the initial value. In addition the percentage of failed modules (fatal failure) is characterized by the C value.
The F value is the combination of the B and C value. That means for F degradation and complete failures are considered, e.g. L70F10 means 10 % of the LED modules may fail or be below 70 % of the initial luminous flux.
Photometric characteristics
The specified colour coordinates are measured integral in thermal saturated stage at specified tp. The current impuls depends on the module type.
The ambient temperature of the measurement is ta = 25 °C. The measurement tolerance of the colour coordinates are ± 0.01.
Miscellaneous
Insulation and electric strength testing of luminaires
Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production.
According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an insulation test with 500V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal.
The insulation resistance must be at least 2MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500V AC (or 1.414 x 1500V DC). To avoid damage to the electronic devices this test must not be conducted.
Conditions of use and storage
Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %)
Storage temperature: -30 °C up to max. +80 °C
The devices have to be within the specified temperature range (ta) before they can be operated
Ready2apply is a product range from Tridonic designed for quick and easy installation of LED lighting, primarily focusing on emergency lighting and downlight solutions. These products are engineered to be “out-of-the-box” solutions, integrating the LED module, driver, optics, and heat sink into a single unit.
Here are the key details regarding the EM ready2apply emergency lighting range:
Key Features and Benefits
All-in-One Design: Combines the LED driver, module, battery, and optics in a compact housing, allowing for fast, cost-effective, and simple installation.
Versatile Optics: Each unit includes three easily interchangeable lenses for different lighting requirements: anti-panic, escape route, and spot lighting.
Long-Life Battery: Utilizes Lithium Iron Phosphate (LiFePO4) batteries with a 3-year guarantee and an 8-year design life.
Easy Installation: Designed for small ceiling holes (40–43 mm diameter, or 68–72 mm for specific PRO models), with integrated strain relief and tool-free mounting options.
Performance: Offers high colour rendering (CRI > 80) and a color temperature of 6,500 K.
Product Variants
The EM ready2apply range includes:
Recessed Downlights: Suitable for ceilings with void heights as small as 80 mm.
Surface-Mounted Luminaires: Features BESA compatible mounting and is available in black or white.
Exit Signs: Available for 30m viewing distances, with 3-hour duration.
Test Functionality:
BASIC: Manual testing.
SELFTEST: Automatic testing.
PRO: DALI interface for central monitoring.
Applications
Ready2apply is suitable for professional lighting applications, including:
- Shops and retail environments
- Hotels
- Emergency and escape route lighting
The Engine DLA ready2apply variant is specifically designed as a quick-replacement solution for conventional downlights using compact fluorescent lamps (CFLs).
Tridonic are a Zumtobel Group company, founded in 1956 in Dornbirn, Austria. For more than 60 years, they have been a driving force in the development of professional lighting solutions.
Today, Tridonic is a world-leading provider of lighting technology for professional applications, including office buildings, and retail outlets, hotels and restaurants, the education industry and outdoor lighting sectors.
In Tridonics’ extensive range of energy-efficient dimmable and non-dimmable LED drivers they offer the right products for every indoor and outdoor application – from cost-efficient LED drivers in proven Tridonic quality to premium products that give you maximum flexibility and convenience.
Tridonics’ dimmable LED drivers can be controlled with different analog and digital dimming signals. Tridonic basicDIM Wireless products allow wireless control without additional wiring.
Need to know more about Tridonic 28002242 DLA G2 100mm 1000lm 840 SNC EM MOD – Complete ready2apply Solution?
You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.











