Tridonic 89800576 EMconverterLED BASIC 203 MH/LiFePO4 50V
89800577
Tridonic 89800576 EMconverterLED BASIC 203 MH/LiFePO4 50V
Self contained emergency lighting LED driver for manual testing
For LED modules with a forward voltage of 10 – 54 V
SELV for output voltage < 60 V DC
Low profile casing (21 x 30 mm cross-section)
£34.77
Ex.VAT Inc.VAT£41.72
Description
Tridonic 89800576 EMconverterLED BASIC 203 MH/LiFePO4 50V
89800576 Description
Self contained emergency lighting LED driver for manual testing
For LED modules with a forward voltage of 10 – 54 V
SELV for output voltage < 60 V DC
Low profile casing (21 x 30 mm cross-section)
For luminaire installation
Compatible with Tridonic’s LLE FLEX modules (ADV, EXC)
Nominal lifetime up to 100,000 h
EM = Emergency
89800576 Properties
Non maintained operation
1 or 3 h rated duration
Operating time selectable with plug (duration link)
Compatible with all dimmable and non-dimmable constant current LED driver (see data sheet, LED driver compatibility)
3-pole technology: 2-pole LED module changeover and delayed power switching for the LED driver
Automatic shutdown of output if LED load is out of range
Constant power output
Maximum light output for all LED modules
Electronic charge system
Deep discharge protection
Short-circuit-proof battery connection
Polarity reversal protection for battery provided by 3-pole connector
Automatic detection of the connected battery technology (NiMH or LiFePO4 batteries)
89800576 Batteries
High-temperature cells
NiMH or LiFePO4 batteries; See our 3QQMH4-0LFT4 for suitability to the application
LA or 18650 cells
NiMH: 4 years design life
LiFePO4: up to 12 years design life
8 years guarantee for LiFePO4 batteries
LiFePO4 batteries with Tridonic LiFeGuard
For battery compatibility refer to data sheet, battery selection
89800576 Common Data
89800576 Electrical data
Rated supply voltage 220 – 240 V
Mains frequency 50 / 60 Hz
Forward voltage range LED module 10 – 54 V
Output current Refer to data sheet
Starting time < 0.5 s from detection of emergency event
Overvoltage protection 320 V (for 48 h)
U-OUT (including open- / short-circuit and double load) 60 V
Max. open circuit voltage 60 V
Battery charging time 24 h
Ambient temperature ta -5 … +55 °C
Max. casing temperature tc 75 °C
Mains voltage changeover threshold According to EN 60598-2-22
Mains surge capability (between L – N) 1 kV
Mains surge capability (between L/N – PE) 2 kV
Type of protection IP20
Lifetime up to 100,000 h
Dimensions L x W x H 179 x 30 x 21 mm
89800576 Dimensions
Side view
Top view
89800576 Standards
• EN 61347-1
• EN 61347-2-13
• EN 61347-2-7
• EN 55015
• EN 61000-3-2
• EN 61000-3-3
• EN 61547
• EN 60068-2-64
• EN 60068-2-29
• EN 60068-2-30
• EN 62384
• according to EN 50172
• according to EN 60598-2-22
Glow-wire test
according to EN 61347-1 with increased temperature of 850 °C passed
Insulation and electric strength testing of luminaires
Electronic LED-drivers can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an insulation test with 500VDC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The insulation resistance must be at least 2 MΩ.
As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1,500VAC (or 1,414 x 1,500VDC). To avoid damage to the electronic devices this test must not be conducted.
89800576 Thermal details and lifetime
89800576 Lifetime
Average lifetime 50,000 hours under rated conditions with a failure rate of less than 10 %. Average failure rate of 0.2 % per 1000 operating hours.
The emergency lighting LED driver is designed for a lifetime stated above under reference conditions and with a failure probability of less than 10 %. The relation of tc to ta temperature depends also on the luminaire design.
If the measured tc temperature is approx. 5 K below tc max., ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request.
89800576 Installation / Wiring
89800576 Wiring diagram
One or more LED modules with a total forward voltage of 10 to 54 V can be connected to the EM converterLED 50V module. These LED module(s), marked with “Emergency” are operated in emergency mode from the associated battery. In normal mains mode all LED modules are operated by the LED driver from the mains supply.
Use of the test switch:
For checking the device function press the test switch for a minimum of 3 seconds.
89800576 Wiring type and cross section
Solid wire with a cross section of 0.5 – 1.5 mm². Strip 8 – 9 mm of insulation from the cables to ensure perfect operation of terminals.
Wiring: LED module/LED driver/supply
89800576 Wiring guidelines
• The LED terminals, battery, indicator LED and test switch terminals are classified as SELV (output voltage < 60 V DC). Keep the wiring of the input terminals separated from the wiring of the SELV classified terminals or consider special wiring (double insulation, 6 mm creepage and clearance) when these connections should be kept SELV.
• The output to the LED is DC but has high frequency content, which should be considered for good EMC compliance.
• Separate LED leads from the mains and DALI connections and wiring for good EMC performance.
• Maximum lead length on the LED terminals is 3 m. For a good EMC performance keep the LED wiring as short as possible.
• Route the secondary wires (LED module) in parallel to ensure good EMC performance.
• Maximum lead length for the Test switch and Indicator LED connection is 1 m. Separate the test switch and Indicator LED wiring from the LED leads to prevent noise coupling.
• Battery leads are specified with 0.5 mm cross section and a length of 0.8 m
• Protect the wiring against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.) to avoid the damage of the control gear. To ensure that a luminaire containing LED emergency units complies with EN 55015 for radio frequency conducted interference in both normal andemergency mode it is essential to follow good practice in the wiring layout.
Within the luminaire route the switched and unswitched 50Hz supply wiring as short as possible and keep it as far away as possible from the LED leads. Through wiring may affect the EMC performance of the luminaire. Do not exceed the max. length of LED leads to the LED module.
Note that the length of the EM converterLED leads to the LED module is added to the length of the leads from the LED driver to the EM converterLED module when considering the max. permitted lead length of the LED driver.
Maximum lead length
LED 3 m (6 m loop)1
Status indication LED 1 m
Batteries 0.8 m
1 Note: The length of LED leads to the LED module must not be exceeded. Note that the length of the EM converterLED leads is added to the length of the leads from the LED driver to the EM converterLED module when considering max. permitted lead length of the LED driver. Leads should always be kept as short as possible.
Use of different phases
The use of different phases for switched line and unswitched line is allowed. When using different phases, the unswitched line must fail if the switched line fails. This is required to assure correct switching into emergency mode. It can be realised with a relay.
Compatibility with LLE FLEX modules
The EM converterLED can be used within certain restrictions to operate constant voltage LED loads from the Tridonic LLE FLEX (ADV, EXC) product range. A certain minimum length of the LLE FLEX is required for correct operation.
Detailed information in the download area of the ST and PRO product pages at www.tridonic.com (EM converterLED manual).
89800576 Mechanical values
Housing properties for the 89800576
• Casing manufactured from polycarbonate.
• Type of protection: IP20
• Max. torque at the mounting screws: 0.8 Nm
Mechanical data accessories for the 89800576
LED status indicator
• Green
• Mounting hole 6.5 mm diameter, 1 – 1.6 mm thickness
• Lead length 0.3 m / 0.6 m / 1.0 m
• Insulation rating: 90 °C
• Plug connection
Test switch
• Mounting hole 7.0 mm diameter
• Lead length 0.55 m
• Plug connection
Battery connection
• Plug connection 0.3 m
• Extension 0.5 m
LED driver compatibility
The EM converterLED emergency unit use 3 pole technology and is compatible with most LED drivers on the market, however it is important to check that the rating of the LED driver does not exceed the values specified below:
• The max. allowed output current rating of the associated LED driver is 2 A eff (current rating of the terminals of EM converterLED) and 2.4 A peak (current rating of switching relays of EM converterLED)
• The max. allowed inrush current rating of the associated LED driver is 60 A peak for 1 ms or 84 A for 255 μs (inrush current rating of switching relay of EM converterLED)
• The max. allowed output voltage (U-OUT) of the associated LED driver applied to the EM converterLED output is 450 V (voltage withstand between adjacent contact of the single switching relay of the EM converterLED)
• The max. allowed LED load of the associated LED driver is 150 W in operation. The load must be an LED module. Check compatibility with short function tests (duration of several seconds).
89800576 Functions
Duration link selection
Emergency lighting LED driver supplied with duration link in 3 hours position.
The position of the link will only be read on first power up. If it is changed afterwards both the battery and mains supply must be disconnected for 10 seconds to enable the EM converterLED to read the new link position on reconnection of the battery and mains. It will lead to a false battery failure indication if the link is changed after installation without this reset.
Status indication LED
System status is indicated by a green LED.
Note:
The status indication LED switches off if the battery does not reach the full capacity (3.6V battery voltage) within 20 – 24 hours. If this occurs disconnect the mains voltage and operate the device in emergency mode for approximately one hour. Afterwards apply the mains voltage again and recharge the battery for 24 hours. If the failure occurs again replace the battery.
Safety (LiFeGuard)
Note: LiFeGuard ensures safe and reliable battery operation by offering a comprehensive three-layered safety system. It addresses the cell, battery pack and emergency driver.
Deep discharge protection
When the battery remains connected without charging for a long period of time after the battery cut off of the driver the battery voltage can still drop. To make sure the cells are not damaged by this voltage drop, the battery protection prevents the battery from further discharge below 2.0 V.
Overcharge protection
If in case of an error or the use of a wrong driver the battery gets overcharged the battery protection will disconnect the battery from the driver at a voltage of 3.9 V. A discharge of the battery is still possible after the protection circuit was triggered to guarantee emergency operation.
Short-circuit protection
In case of a short circuit the battery protection opens the connection to the driver and the output is therefore free of voltage. The output will be reactivated again when the short circuit is removed.
Overtemperature protection for the 89800576
The battery is protected against temporary thermal overheating. If the temperature limit is exceeded the further charging of the battery is no longer possible. The temperature protection is activated below approx. 0 °C and above approx. +60 °C. The discharging of the battery is still possible to guarantee emergency operation. The charging is automatically activated when the temperature is within the range of 0 to 60°C again.
Battery has built in thermal sensor for safe charging. Mount battery away from heat source. Positioning of the thermal sensor see battery data sheet.
Wiring batteries
To inhibit inverter operation disconnect the batteries by removing the connection at battery side.
For further informations refer to corresponding battery datasheet.
Storage, installation and commissioning the 89800576
Relevant information about storage conditions, installation and commissioning are provided in the battery datasheets.
Miscellaneous information for the 89800576
Maximum number of switching cycles
EM converterLEDs are tested with 50,000 mains switching cycles of the associated LED driver.
Battery replacement
After a battery replacement and a subsequent full charge cycle (24 h) a duration test is mandatory to prove that with the new battery the rated duration is achieved.
Mains-connected transformers
The EM converterLED does not contain mains-connected windings of transformers.
LED emergency modules are essential, compact devices that convert standard LED fixtures into emergency lighting, providing back-up illumination for at least 3 hours during power outages. They feature rechargeable batteries (Ni-Cd, NiMH, or LiFePO4) and automatically switch on when main power fails, often used in commercial and industrial settings.
Key Features & Functionality
Emergency Duration: Typically provides 3 hours of illumination.
Charging Time: Full capacity recharge usually requires 24 hours.
Compatibility: Designed for a wide range of LED drivers and loads, commonly operating in the 3-55V or 6-55V range.
Safety & Compliance: Includes deep discharge protection for batteries and green status LED indicators for monitoring. They help meet building safety regulations.
Types: Available in Maintained (stays on/dimmed when power fails) or Non-Maintained (turns on only during a power failure).
Installation & Components
Components: The module, or inverter, comes with a battery pack and is often installed within the existing light fixture (integral) or in a ceiling void.
Installation: Designed for easy integration into LED battens, panels, and downlights.
Maintenance: Features test buttons to simulate power failure for routine checks.
Common Applications
Offices, schools, and hospitals.
Emergency escape routes and exit lighting.
Retail and public buildings.
Suitable for LED T8 tubes, panels, and bulkheads
Tridonic are a Zumtobel Group company, founded in 1956 in Dornbirn, Austria. For more than 60 years, they have been a driving force in the development of professional lighting solutions.
Today, Tridonic is a world-leading provider of lighting technology for professional applications, including office buildings, and retail outlets, hotels and restaurants, the education industry and outdoor lighting sectors.
In Tridonics’ extensive range of energy-efficient dimmable and non-dimmable LED drivers they offer the right products for every indoor and outdoor application – from cost-efficient LED drivers in proven Tridonic quality to premium products that give you maximum flexibility and convenience.
Tridonics’ dimmable LED drivers can be controlled with different analog and digital dimming signals. Tridonic basicDIM Wireless products allow wireless control without additional wiring.
Need to know more about Tridonic 89800576 EMconverterLED BASIC 203 MH/LiFePO4 50V?
You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.