ELP LDM60D/K – DALI 2 Certified Emergency Conversion Kit 12V – 55V (2.0W)
LDM60D/K
ELP LDM60D/K
The LDM60D/K consists of module,LiPO4 battery and LED indicator.
The ELP LDM DALI-2 NFC range of emergency LED control gear allows maintained operation of high-power LED modules, when used in conjunction with the standard mains voltage LED control gear.
£51.11
Ex.VAT Inc.VAT£61.33
Less Than 10 Available!
Description
ELP LDM60D/K
The ELP LDM DALI-2 NFC range of emergency LED control gear allows maintained operation of high-power LED modules, when used in conjunction with the standard mains voltage LED control gear. The control gear also provides an integrated DALI power supply for connection to other DALI devices, which can be optionally activated using a NFC programmer.
The emergency control gear incorporates a module/charger and a high temperature Lithium Iron Phosphate battery. In the event of a mains failure an integral 2-pole relay disconnects the LED lighting load from the mains control gear and then connects it to the emergency control gear which operates the LED module at an optimum light output for the rated duration.
LDM60D/K Enabled Features
• The Near Field Communication (NFC) interface allows for the optional activation of an integrated DALI power supply and also the downloading of diagnostics to assist in any site issues.
• An App is available that can be downloaded onto a phone or tablet which can read stored operating parameters including information such operating hours, how many tests have been performed, module thermals , etc. This is a unique feature that highlights installation conditions and aids fault diagnostics.
• The LED current in emergency mode is automatically adjusted for maximum light output and is constant for the entire rated duration.
• Smart charging of the Lithium Iron Phosphate batteries which have protection circuit fitted including thermal sensing. NB: Lithium Iron Phosphate batteries offer long life (up to 8 years)
• The LDM range is available with fully interoperable DALI control and reporting function and comes with an integrated DALI PSU. Automatic Self-Test is enabled when no DALI bus is connected.
LDM60D/K Description
It is important to note that some LED mains control gear should not be operated with an open circuit load, to overcome this problem when first powering up the LDM range features a live in/ live out relay which ensures the load is in place before the mains driver is powered up.
In Self-test mode the function and duration tests will take place at randomized times. If required, duration testing can be programmed by turning the unswitched supply off and on 3 times in 10 seconds at the required time. Note the function test will occur weekly at the same time.
To ensure the correct operation of each type of LED module the correct LDM equipment should be selected. The total forward operating voltages of the LED module / arrays connected should be used to determine the appropriate LDM control gear.
As default, the integral DALI power supply will be disabled. Please see the order codes on the last page if you would like this to be enabled or for the appropriate battery, indicator LED etc.
LDM60D/K Common Data
LDM60D/K Environmental
Ingress protection IP20
Module rated operating ambient temperature -20°C to 50°C
Battery rated operating ambient temperature 0°C to 55°C
Maximum case temperature 70°C
LDM60D/K Mains Operation
Rated voltage supply 220/240 VAC
Mains frequency 50/60 Hz
Mains supply current <18mA
Mains supply power 4W
Power factor (with integrated DALI power supply enabled) 0.7C
Mains overvoltage protection 320V for 1 hour
Indicator LED 2 wire red/green colour
Maximum power that can be switched via relay contacts 150W
Maximum current that can be switched via relay contacts 2A
Maximum voltage that can be switched via relay contacts 250VAC/220VDC
LDM60D/K Emergency Operation
Emergency duration 1 or 3 hours
Battery chemistry type LiFePO₄
Number and type of high temperature cells 2 x LiFePO₄ 1.8Ah 18650 cells B091T
Battery recharge period <24 hours
Time to full illuminance <0.5 seconds
Short-circuit-proof battery connection, over charge protection, over discharge protection, polarity reversal protection, deep discharge protection and thermal protection Battery is fitted with 3 wires/connector to enable the thermal protection
Battery charge current 0-160mA
Battery discharge current range (at nominal battery voltage) LiFePO₄ 1.8Ah 18650 cells 325mA to 500mA (375mA)
Module output voltage range (nominal power) LDM60D 12V to 55V (2.0W)
LDM60D/K DALI Power Supply
Integrated DALI power supply minimum/maximum output current 50mA/60mA
The NFC interface allows for optional activation of the DALI power supply Default is disabled
No other DALI power supply is to be connected in parallel and the maximum volt drop for the DALI wires is 2V
DALI terminals are proof against mains voltage
LDM60D/K Insulation
Insulation between mains and battery, LED module, indicator LED Double or reinforced insulation
Insulation between mains and DALI Basic insulation
Output voltage from LDM60D, LDM60MOD, LDM60HOD and LDM606WD is SELV < 60 V DC
Black Box Recording
A record is kept of the number and length of emergency/mains operations and control gear/battery temperatures. This information can be downloaded via the NFC interface or a DALI controller
LDM60D/K Mechanical
Module outside dimensions L178mm x W30mm x H21mm
Fixing centres 170mm
Electrical connections Push wire terminals
LDM60D/K Standards Compliance
IEC 61347-1, IEC 61347-2-7, IEC 61347-2-13 & IEC 60598-2-22 Yes
IEC 62034, IEC 62386-101*, IEC 62386-102*, IEC 62386-202* & IEC 62386-250 Yes
IEC 55015 & IEC 61547 Yes
Marks UKCA, CE Yes
DALI NFC LED Emergency Modules (such as ELP LDM DALI-2) are smart, self-contained control gears that manage LED luminaires during mains failures and facilitate intelligent, two-way, wireless communication with lighting management systems. They use NFC to wirelessly configure current, diagnostics, and DALI addresses, offering automated testing and monitoring in compliance with DALI-2 Part 202 standards.
Key Aspects of DALI NFC LED Emergency Modules:
Emergency Functionality: In a power failure, a 2-pole relay switches the LED load from the mains driver to the emergency gear, operating at an optimal, reduced light level (via battery power) for a rated duration, usually 3 hours.
NFC Configuration: Allows for wireless, on-site, or pre-installation programming of output current (in 0.1mA/1mA steps), emergency light levels (EOFI), and DALI diagnostics
DALI-2 / Part 202 Compliance: Ensures interoperability between vendors, allowing monitoring of battery status, lamp faults, and testing, which reduces maintenance time.
Battery Technology: Typically, these modules are paired with high-temperature Lithium Iron Phosphate (LifePO4) or Nickel Cadmium (NiCd) batteries.
Efficiency & Flexibility: They support high-efficiency dimming (1-100%) and are often suitable for both maintained and non-maintained emergency lighting systems.
Benefits of DALI + NFC in Emergency Lighting:
Reduced Stock: One module can be configured for many different luminaires, eliminating the need to stock multiple current-specific drivers.
Automatic Testing: Complies with safety regulations by performing automated, logged tests.
Digital Monitoring: Facilities managers can track energy usage and battery performance remotely, simplifying maintenance
Established in 1995 and based in the South-East, we are a team of experts with unrivalled knowledge and experience in safety lighting products, devices, and electronic circuits. We hold a vast range of stock onsite which means no long lead times for your commercial project. Therefore, if we have the products in stock that you need, we aim to get them to you the very next day.
We don’t just sell products we also develop them in-house. We specialise in manufacturing emergency lighting equipment and have vast engineering capabilities, so we can supply you with exactly what you need while meeting legal requirements. We also customise existing products and create bespoke orders as part of our assembly and emergency lighting conversion work. Our technical support team is always available to give respected advice and support.
Our offering includes comprehensive testing to ensure all products are fully functioning and compliant with current regulations when they leave our site.
Need to know more about ELP LDM60D/K – DALI 2 Certified Emergency Conversion Kit 12V – 55V (2.0W)?
You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.