28000666

Tridonic 22185123 PCA 2×18 TC ECO Y II – Limited Stock

22185123

SKU:22185123

Tridonic 22185123 PCA 2×18 TC ECO Y II

• Intelligent Temperature Guard (overtemperature protection)
• Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
• Optimum filament heating in any dimmer setting
• Disconnection of filament heating from a dimming level of approx. 90 % for maximum energy efficiency (SMART-Heating concept)

£51.89
Ex.VAT
Inc.VAT£62.27

Less Than 10 Available!

Description

Tridonic 22185123 PCA 2×18 TC ECO Y II

22185123 Description

• Processor-controlled ballast with y II inside
• Highest possible energy class CELMA EEI = A1 BAT1
• Noise-free precise control via DALI or DSI signal, switchDIM or corridorFUNCTION
• Nominal life up to 100,000 h (at ta 50 °C with a failure rate max. 0.2 % per 1,000 h)
• OEM-specific reserved memory areas

22185123 Interfaces

• DALI
• DSI
• switchDIM (with memory function + selectable dimming rate)
• corridorFUNCTION (3 preprogrammed profiles)
• Integrated SMART interface for function with SMART Sensor 5D 19f and corridor FUNCTION plugs.

22185123 Functions

• Intelligent Temperature Guard (overtemperature protection)
• Optimum filament heating in any dimmer setting
• Disconnection of filament heating from a dimming level of approx. 90 % for maximum energy
• Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)

https://www.tridonic.com/en/int

22185123 Technical Information

Mains voltage range 220 – 240 V
AC voltage range 198 – 264 V
DC voltage range 176 – 280 V (lamp start ≥ 198 V DC)
Mains frequency 0 / 50 / 60 Hz
Overvoltage protection 320 V AC, 1 h
Typ. power input on standby < 0.2 W
Protective hot restart 0.5 s for AC / 0.2 s for DC
Dimming range 3 – 100 %
Lamp start possible from 3 %
Operating frequency ~ 40 – 130 kHz
Type of protection IP20

22185123 Standards

EN 55015
EN 60929
EN 61000-3-2
EN 61347-2-3
EN 61547
Suitable for emergency installations according to
EN 50172
CISPR 15
CISPR 22
IEC 60929
IEC 61000-3-2
IEC 61347-2-3
IEC 61547
IEC 62386 (according to DALi standard V1)

22185123 Lamp starting characteristics

Warm start
Starting time 0.5 s with AC
Starting time 0.2 s with DC
Start at any dimming level

22185123 AC operation

Mains voltage
220–240 V 50/60 Hz
198–264 V 50/60 Hz including safety
tolerance (±10%)
198–254 V 50/60 Hz including performance
tolerance (+6%/-8%)

22185123 DC operation

220–240 V 0 Hz
198–254 V 0 Hz certain lamp start
176–280 V 0 Hz operating range
Use in emergency lighting installations according to EN 50172 or for emergency luminaires according to EN 61347-2-3 appendix J.

Dimming

Dimming curve is adapted to the eye sensitiveness.
Dimming range 3% to 100%
Digital control with:
• DSI signal: 8 bit Manchester Code Speed 3% to 100% in 1,16 s
• DALI signal: 16 bit Manchester Code Maximum speed 3% to 100% in 550ms (adjustable between 100ms and 90 s)
Programmable parameter:
Minimum dimming level
Maximum dimming level
Default minimum = 3%
Default maximum = 100%

Control input (DA/D1, DA/D2)

Digital DSI signal, push-to-make switch (switchDIM) or the digital control signal DALI/DSI can be wired on the same terminals (DA/D1 and DA/D2).

Digital signal DALI/DSI

The control input is non-polar and protected against accidental connection with a mains voltage up to 264 V. The control signal is not SELV. Control cable has to be installed in accordance to the requirements of low voltage installations. Different functions depending on each module.

22185123 Wiring type and cross section

The wiring can be in stranded wires with ferrules or solid with a cross section of 0.5–1.5 mm². Strip 9.5 mm of insulation from the cables to ensure perfect operation of the push-wire terminals.

With standard solid wire 0.5/0.75mm² the capacitance of the lead is 30–80 pF/m. This value is influenced by the way the wiring is made. Lamp connection should be made with symmetrical wiring. Hot leads (10, 11, 16, 17) and cold leads (12, 13, 14, 15) should be separated as much as possible. When using two or more dimmable ballasts in one luminaire with separate dimming controls, the lamp leads must be kept separate.

Tridonic are a Zumtobel Group company, founded in 1956 in Dornbirn, Austria. For more than 60 years, they have been a driving force in the development of professional lighting solutions.

Today, Tridonic is a world-leading provider of lighting technology for professional applications, including office buildings, and retail outlets, hotels and restaurants, the education industry and outdoor lighting sectors.

Need to know more about Tridonic 22185123 PCA 2×18 TC ECO Y II – Limited Stock?

You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.







    You may also be looking for...