Tridonic 28004041 LC 14/100-400/42 o4a NF SC EXC3 – Easily Programble via DALI or NFC
28004041
Tridonic 28004041 LC 14/100-400/42 o4a NF SC EXC3
28004041 Description
NEW: lumDATA (DALI-2 part ext. 251, 252 and 253)
Can be either used build-in or independent with clip-on strain-relief (28001168)
Dimming range 1 to 100 % (min. 5 mA)
£28.21
Ex.VAT Inc.VAT£33.85
Less Than 10 Available!
Description
Tridonic 28004041 LC 14/100-400/42 o4a NF SC EXC3
28004041 Description
NEW: lumDATA (DALI-2 part ext. 251, 252 and 253)
Can be either used build-in or independent with clip-on strain-relief (28001168)
Dimming range 1 to 100 % (min. 5 mA)
For luminaires of protection class I and protection class II
Temperature protection as per EN 61347-2-13 C5e
Adjustable output current between 100 – 400 mA via NFC or DALI
Max. output power 14 W
Up to 83 % efficiency
Lowest power input on stand-by < 0.35 W
28004041 Housing properties
Casing: polycarbonate, white
Type of protection IP20
28004041 Interfaces
Near field communication (NFC)
one4all (DALI-2 DT 6, switchDIM, corridorFUNCTION)
Terminal blocks: 45° push terminals
28004041 Functions
Adjustable output current in 1-mA-steps (NFC, DALI)
Enhanced constant light output function (eCLO)
Protective features (overtemperature, short-circuit, overload, no-load)
Suitable for emergency escape lighting systems acc. to EN 50172
28004041 Benefits
Flexible configuration via companionSUITE (NFC, DALI)
Application-oriented operating window for maximum compatibility
Best energy savings due to low stand-by losses and high efficiency
In-field programming possible after installation with NFC interface
Typical applications for the 28004041
For downlight, spotlight and decorative applications
28004041 Common Data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
DC voltage range 176 – 280 V
Mains frequency 0 / 50 / 60 Hz
Overvoltage protection 320 V AC, 48 h
Typ. rated current (at 230 V, 50 Hz, full load) 12 83 mA
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) 2 17.3 mA
Leakage current (at 230 V, 50 Hz, full load) 12 < 250 µA
Max. input power 17.165 W
Typ. efficiency (at 230 V, 50 Hz, full load) 2 83 %
λ (at 230 V, 50 Hz, full load) 1 0.92C
λ (over full operating range) 0.32C – 0.92C
Typ. power consumption on stand-by 3 < 0.35 W
In-rush current (peak / duration) 2.71 A / 38 µs
THD (at 230 V, 50 Hz, full load) 1 < 10 %
Starting time (AC mode) < 700 ms
Starting time (DC mode) < 500 ms
Switchover time (AC/DC) 4 < 800 ms
Turn off time (at 230 V, 50 Hz, full load) < 50 ms
Output current tolerance 15 ± 5 %
Max. output current peak (non-repetitive) ≤ output current + 20 %
Output LF current ripple (< 120 Hz) ± 2 %
Output P_ST_LM (at full load) ≤ 1
Output SVM (at full load) ≤ 0.4
Max. output voltage (U-OUT) 60 V
Dimming range 1 – 100 % (min. 5 mA)
Mains surge capability (between L – N) 6 1 kV
Mains surge capability (between L/N – PE) 2 kV
Burst protection 7 1 kV
Burst / surge peaks output side against PE < 3 kV
Ambient temperature ta -20 … +50 °C
Max. casing temperature tc 74 °C
Type of protection IP20
Lifetime up to 100,000 h
Dimensions L x W x H 97 x 43 x 30 mm
28004041 Standards
EN 55015
EN 61000-3-2
EN 61000-3-3
EN 61000-4-4
EN 61000-4-5
EN 61347-1
EN 61347-2-13
EN 62384
EN 61547
EN 62386-101 (DALI-2)
EN 62386-102 (DALI-2)
EN 62386-207 (DALI-2)
According to EN 50172 for use in central battery systems
According to EN 60598-2-22 suitable for emergency luminaire
Glow wire test
According to EN 61347-1 with increased temperature of 850 °C passed.
28004041 Wiring
28004041 Wiring type and cross section
For wiring use stranded wire with ferrules or solid wire from 0.2–1.5 mm².
Strip 8.5–9.5 mm of insulation from the cables to ensure perfect operation of the push-wire terminals.
Use one wire for each terminal connector only
28004041 Wiring guidelines
• The cables should be run separately from the mains connections and mains cables to ensure good EMC conditions.
• The LED wiring should be kept as short as possible to ensure good EMC.
The max. secondary cable length is 2 m (4 m circuit), this applies for LED output.
• To comply with the EMC regulations run the secondary wires (LED module) in parallel.
• Secondary switching is not permitted.
• The LED driver has no inverse-polarity protection on the secondary side.
Wrong polarity can damage LED modules with no inverse-polarity protection.
• Wrong wiring of the LED driver can lead to malfunction or irreparable damage.
• To avoid damage of the Driver, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.).
Replace LED module
1. Mains off
2. Remove LED module
3. Wait for 30 seconds
4. Connect LED module again
Hot plug-in or secondary switching of LEDs is not permitted and may cause a very high current to the LEDs.
Installation note
Max. torque at the clamping screw: 0.5 Nm / M4
Make sure that the LED driver is operated within the given window under all operating conditions. Special attention needs to be paid at dimming and DC emergency operation as the forward voltage of the connected LED modules varies with the dimming level, due to the implemented amplitude dimming technology. Coming below the specified minimum output voltage of the LED driver may cause the device to shut-down.
With appropriate software and interface different functions can be activated and various parameters can be configured in the LED driver.
Software / Programming / Interfaces
The Driver supports the following software and interfaces:
Software / hardware for configuration:
• companionSUITE (deviceGENERATOR, deviceCONFIGURATOR, deviceANALYSER)
• masterCONFIGURATOR
Interfaces for data transfer:
• NFC
• Control input DALI
• Control input switchDIM
Control input DALI
The control input is non-polar for digital control signals (DALI).
The control signal is not SELV. The control cable has to be installed in accordance to the requirements of low voltage installations.
Digital control with:
• DALI signal: 16 bit
Dimming is realized by amplitude dimming
Control Input switchDIM
A standard pushbutton (switchDIM) can be wired on the terminals (DA/N and DA/L).
Integrated switchDIM function allows a direct connection of a pushbutton for dimming and switching.
Brief push (< 0.6 s) switches LED driver ON and OFF. The dimm level is saved at power-down and restored at power-up.
When the pushbutton is held, LED modules are dimmed. After repush the LED modules are dimmed in the opposite direction.
In installations with LED drivers with different dimming levels or opposite dimming directions (e.g. after a system extension), all LED drivers can be synchronized to 50 % dimming level by a 10 s push.
Use of pushbutton with indicator lamp is not permitted.
Constant Current DALI NFC LED drivers combine precise 300-1000mA+ output, DALI-2 dimming protocols (DT6/DT8), and wireless NFC configuration for rapid customization. They enable ultra-deep dimming 0.01%-100%, support Constant Lumen Output (CLO), and are programmed via smartphone/tools to reduce inventory, operating safely in indoor, SELV, or linear environments.
Key Features and Capabilities NFC Programming: Allows for wireless, fast, and precise configuration of output current (in 0.1mA steps), DALI address, groups, and scenes. This can be done without powering the driver.
DALI-2 Certified: Compatible with DALI DT6 (single colour) and DT8 (tunable white) protocols.
Constant Current Output: Supplies stable current (typically 300 to 1000) across a wide voltage range.
Dimming Performance: Offers smooth, flicker-free, and ultra-deep dimming (down to 0.01%).
Energy Management: Features CLO (Constant Lumen Output) to maintain consistent light levels over the driver’s lifetime.
Safety & Reliability: Includes protection against short circuits, over-temperature, and over-current with automatic recovery.
Common Applications and Specifications
Power Ranges: Typically available from 10 to 300W.
Form Factors: Linear or compact, suitable for various fixture designs.
Environment: Mostly IP20-rated for indoor use.
Tridonic are a Zumtobel Group company, founded in 1956 in Dornbirn, Austria. For more than 60 years, they have been a driving force in the development of professional lighting solutions.
Today, Tridonic is a world-leading provider of lighting technology for professional applications, including office buildings, and retail outlets, hotels and restaurants, the education industry and outdoor lighting sectors.
In Tridonics’ extensive range of energy-efficient dimmable and non-dimmable LED drivers they offer the right products for every indoor and outdoor application – from cost-efficient LED drivers in proven Tridonic quality to premium products that give you maximum flexibility and convenience.
Tridonics’ dimmable LED drivers can be controlled with different analog and digital dimming signals. Tridonic basicDIM Wireless products allow wireless control without additional wiring.
Need to know more about Tridonic 28004041 LC 14/100-400/42 o4a NF SC EXC3 – Easily Programble via DALI or NFC?
You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.