28000666

Tridonic 87500922 LC 27W 100-500mA 54V o4a NF SR – DALI 2 Certified

87500922

SKU:87500922

Tridonic 87500922 LC 27W 100-500mA 54V o4a NF SR

Independent constant current LED driver
Dimmable via DALI-2
Dimming range 1 to 100 % (min. 5 mA)
lumDATA (DALI-2 part ext. 251, 252 and 253)
Output current adjustable between 100 –500 mA with DALI or NFC

£23.94
Ex.VAT
Inc.VAT£28.73

Less Than 10 Available!

Quantity Price (each)
1 £23.94
5 £22.55
10+ £21.84

Description

Tridonic 87500922 LC 27W 100-500mA 54V o4a NF SR

87500922 Description

Independent constant current LED driver
Dimmable via DALI-2
Dimming range 1 to 100 % (min. 5 mA)
lumDATA (DALI-2 part ext. 251, 252 and 253)
Output current adjustable between 100 –500 mA with DALI or NFC
Max. output power 27 W
Up to 86 % efficiency
Power input on stand-by < 0.5 W
Nominal lifetime up to 100,000 h

87500922 Housing properties

Casing: polycarbonate, white
Type of protection IP20
Strain relief with loop through function
Interfaces
Near field communication (NFC)
one4all (DALI-2 DT 6, switchDIM, corridorFUNCTION V2)

87500922 Functions

Adjustable output current in 1-mA-steps (NFC, DALI-2)
Fulfills DALI-2 parts: 251 (Luminaire data), 252 (Energy reporting) and 253 (Diagnostics & Maintenance)
Constant light output function (CLO)
Protective features (overtemperature, short-circuit, overload, no-load)
Surge protection voltage 1 kV (L – N)
Suitable for emergency escape lighting systems acc. to EN 50172
For cable cross-sections up to 2.5 mm²

87500922 Benefits

Flexible configuration via companionSUITE (NFC, DALI-2)
Application-oriented operating window for maximum compatibility

Typical applications for the 87500922

For applications in downlight and decorative luminaires

https://www.tridonic.com/en/int/product/87500922

87500922 Common Data

Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
DC voltage range 176 – 270 V
Mains frequency 0 / 50 / 60 Hz
Overvoltage protection 320 V AC, 48 h
Typ. rated current (at 230 V, 50 Hz, full load) 12 145 mA
Typ. current (220 V, 0 Hz, full load, 100 % dimming level) 2 145 mA
Leakage current (at 230 V, 50 Hz, full load) 12 < 700 µA
Max. input power 31.5 W
Typ. efficiency (at 230 V, 50 Hz, full load) 2 86 %

λ (at 230 V, 50 Hz, full load) 0.95
Typ. power consumption on stand-by 3 < 0.5 W
Typ. input current in no-load operation < 28 mA
Typ. input power in no-load operation 0.9 W
In-rush current (peak / duration) 4 A / 90 µs
THD (at 230 V, 50 Hz, full load) 1 < 10 %
Starting time (at 230 V, 50 Hz, full load) 1 < 0.66 s
Starting time (DC mode) < 0.4 s
Switchover time (AC/DC) 4 < 0.4 s
Turn off time (at 230 V, 50 Hz, full load) < 0.2 s

Starting time (stand-by) < 0.5 s
Output current tolerance 15 ± 5 %
Max. output current peak (non-repetitive) ≤ output current + 20 %
Output LF current ripple (< 120 Hz) ± 5 %
Output P_ST_LM (at full load) ≤ 1
Output SVM (at full load) ≤ 0.4
Max. output voltage (U-OUT) 60 V

Dimming range 1 – 100 % (min. 5 mA)
Mains surge capability (between L – N) 1 kV
Mains surge capability (between L/N – PE) 2 kV
Surge voltage at output side (against PE) 3 kV
Type of protection IP20
Lifetime up to 100,000 h
Dimensions L x W x H 160 x 82 x 34 mm

87500922 Standards

EN 55015
EN 61000-3-2
EN 61000-3-3
EN 61000-4-4
EN 61000-4-5
EN 61347-1
EN 61347-2-13
EN 62384
EN 61547
EN 60598-1
EN 62386-101 (DALI-2)
EN 62386-102 (DALI-2)
EN 62386-207 (DALI-2, including part 251, 252, 253)
According to EN 50172 for use in central battery systems
According to EN 60598-2-22 suitable for emergency lighting installations

87500922 Thermal details and lifetime

The LED driver is designed for a lifetime stated above under reference conditions and with a failure probability of less than 10 %.
The relation of tc to ta temperature depends also on the luminaire design.

If the measured tc temperature is approx. 5 K below tc max., ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request.

87500922 Wiring

87500922 Wiring type and cross section

Mains supply wires

For wiring use stranded wire with ferrules or solid wire from 0.5–2.5 mm2. Strip 9–10 mm of insulation from the cables to ensure perfect operation of the push terminals.
Use one wire for each terminal connector only. Use each strain relief channel for one cable only.

Secondary wires (LED module)

For wiring use stranded wire with ferrules or solid wire from 0.5–1.5 mm². Strip 8.5–9.5 mm of insulation from the cables to ensure perfect operation of the push-wire terminals. Use one wire for each terminal connector only. Use each strain relief channel for one cable only.

87500922 Fixing conditions

Dry, acidfree, oilfree, fatfree. It is not allowed to exceed the maximum ambient temperature (ta) stated on the device. Minimum distances stated below are recommendations and depend on the actual luminaire.

Device is not suitable for fixing in corner

87500922 Wiring guidelines

• The cables should be run separately from the mains connections and mains cables to ensure good EMC conditions.
• The LED wiring should be kept as short as possible to ensure good EMC.

The max. secondary cable length is 2 m (4 m circuit).

• To comply with the EMC regulations run the secondary wires (LED module) in parallel.
• Secondary switching is not permitted.
• The LED driver has no inverse-polarity protection on the secondary side.

Wrong polarity can damage LED modules with no inverse-polarity protection.

• Wrong wiring of the LED driver can lead to malfunction or irreparable damage.
• Through wiring of mains is for connecting additional LED driver only.

Max. permanent current of 16 A may not be exceeded.

• To avoid damage of the Driver, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.).

Replace LED module

1. Mains off
2. Remove LED module
3. Wait for 10 seconds
4. Connect LED module again

Hot plug-in or secondary switching of LEDs is not permitted and may cause a very high current to the LEDs

87500922 Electrical values

87500922 Operating window

Make sure that the LED driver is operated within the given window under all operating conditions. Special attention needs to be paid at dimming and DC emergency operation as the forward voltage of the connected LED modules varies with the dimming level, due to the implemented amplitude dimming technology. Coming below the specified minimum output voltage of the LED driver may cause the device to shut-down.

Maximum loading of automatic circuit breakers in relation to inrush current

These are max. values calculated out of continuous current running the device on full load.
There is no limitation due to inrush current.
If load is smaller than full load for calculation only continuous current has to be considered

87500922 Dimming

Dimming range 1 % to 100 %
Digital control with:
• DALI signal: 16 bit Manchester Code
Speed 10 % to 100 % in 0.2 s
Programmable parameter:
Minimum dimming level
Maximum dimming level
Default minimum = 1 %
Programmable range 1 % ≤ MIN ≤ 100 %
Default maximum = 100 %
Programmable range 100 % ≥ MAX ≥ 1 %

87500922 Software / Programming / Interfaces

87500922 Software / programming

With appropriate software and interface different functions can be activated and various parameters can be configured in the LED driver.
The Driver supports the following software and interfaces:
Software / hardware for configuration:
• companionSUITE (deviceGENERATOR, deviceCONFIGURATOR,
deviceANALYSER)
• masterCONFIGURATOR
Interfaces for data transfer:
• NFC
• Control input DALI
• Control input switchDIM

87500922 Nearfield communication (NFC)

The NFC Interface allows wireless communication with the LED driver.
This interface offers the option to write configuration and to read configuration, errors and events with the companionSUITE.

A correct communication between the LED driver and the NFC antenna can only be guaranteed if the antenna is placed directly on the Driver.
Any material placed between the LED driver and the NFC antenna can cause a deterioration of the communication quality.
After programming the device via NFC power up the device one time for one second till the deviceANALYSER can read out the parameters.
We recommend the use of following NFC antenna: www.tridonic.com/nfc-readers
NFC is complied with ISO/IEC 15963 standard.
Changing parameters via NFC shall be done by qualified engineers only.

87500922 Control input DALI

The control input is non-polar for digital control signals (DALI).
The control signal is not SELV. The control cable has to be installed in accordance to the requirements of low voltage installations.
Digital control with:
• DALI signal: 16 bit
Dimming is realized by amplitude dimming.

87500922 Control Input switchDIM

A standard pushbutton (switchDIM) can be wired on the terminals (DA/N and DA/L).
Integrated switchDIM function allows a direct connection of a pushbutton for dimming and switching.

Brief push (< 0.6 s) switches LED driver ON and OFF. The dimm level is saved at power-down and restored at power-up. When the pushbutton is held, LED modules are dimmed. After repush the LED modules are dimmed in the opposite direction.

In installations with LED drivers with different dimming levels or opposite dimming directions (e.g. after a system extension), all LED drivers can be synchronized to 50 % dimming level by a 10 s push.

Use of pushbutton with indicator lamp is not permitted.

87500922 Functions

LED current

The LED output current must be adapted to the connected LED module.
The value is limited by the current range of the respective device.
The priority for current adjustment methods is NFC / DALI (highest priority).
Minimum output current is default.

corridorFUNCTION

A motion detector (corridorFUNCTION) can be wired on the terminals (DA/N and DA/L).

With the corridorFUNCTION and a commercially available motion detector, it is easy to adapt the lighting in one area to its use.

That is, when the area is entered by a person, the lighting dims instantly to a certain brightness and is available in desired strength.

After the area is left by the person, the brightness dims slowly to a smaller value or switches off completely. The individual parameters of the desired profile, such as brightness values or delay times, can be adjusted flexibly and individually.

To activate the corridorFUNCTION without using software a voltage of 230V has to be applied at the DA/N and DA/L connection. The unit will then switch automatically to the corridorFUNCTION. corridorFUNCTION is a very simple tool for controlling gears with conventional pushbuttons or motion sensors.

To ensure correct operation a sinusoidal mains voltage with a frequency of 50 Hz or 60 Hz is required at the control input. Special attention must be paid to achieving clear zero crossings. Serious mains faults may impair the operation of corridorFUNCTION.

Constant Light Output (CLO)

With this function the light output of the LED module can be kept equal over the lifetime. The light output of an LED module reduces over the course of its lifetime. The Constant Light Output (CLO) function compensates for this natural decline by constantly increasing the output current of the LED driver throughout its lifetime.

CLO shall be achieved by limitation of the LED current at the commissioning of the LED driver and providing a linear interpolation of the current over the time, depending on the data points given by the user.

Light level in DC operation

The LED driver is designed to operate on DC voltage and pulsed DC voltage. For a reliable operation, make sure that also in DC emergency operation the LED driver is run within the specified conditions as stated in chapter “4.1 operating window”.

Light output level in DC operation is programmable (0; 1 – 100 %).
Default value is 100 % (EOFi = 0.95).

The voltage-dependent input current of Driver incl. LED module is depending on the used load.
The voltage-dependent no-load current of Driver (without or defect LED module) is for:
AC: < 28 mA
DC: < 6 mA

Power-up fading

The power-up function offers the opportunity to modify the on behavior. The time for fading on can be adjusted in a range of 0.2 to 16 seconds. According to this value, the device dims either from 0 % up to the power-on level.

By factory default no fading time is set (= 0 seconds).

87500922 Protective features

Short-circuit behaviour

In case of a short-circuit at the LED output the LED output is switched off. After restart of the LED driver the output will be activated again. The restart can either be done via mains reset or via the DALI interface.

No-load operation

The LED driver will not be damaged in no-load operation. The output will be deactivated and is therefore free of voltage. When connecting an LED load, restart the device to activate the LED output.

Overload protection

If the maximum load is exceeded by a defined internal limit, the LED driver turns off the LED output. After restart of the LED driver the output will be activated again.
The restart can either be done via mains reset or via the DALI interface.

Overtemperature protection

The LED driver is protected against temporary thermal overheating. If the temperature limit is exceeded the LED driver will switch off. It restarts automatically.

The temperature protection is activated above tc max. The activation temperature differs depending on the LED load. On DC operation this function is deactivated to fulfill emergency requirements.

Insulation

The LED driver is double insulated.

87500922 Miscellaneous

Insulation and electric strength testing of luminaires

Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production.

According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an insulation test with 500V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal.

The insulation resistance must be at least 2MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500V AC (or 1.414 x 1500V DC). To avoid damage to the electronic devices this test must not be conducted.

Maximum number of switching cycles

All LED driver are tested with 50,000 switching cycles. The actually achieved number of switching cycles is significantly higher.

Conditions of use and storage

Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %)
Storage temperature: -40 °C up to max. +80 °C

The devices have to be acclimatised to the specified temperature range (ta) before they can be operated.

Constant current compact DALI-2 NFC LED drivers are advanced, small-form-factor power supplies for LED lighting, combining precise current control with DALI-2 digital addressing and NFC programming. They allow for rapid, wireless configuration of output current (in 0.1mA steps) and DALI parameters, ideal for efficient, dimmable, and flexible fixture designs.

Key Features and Benefits

Compact & High Efficiency: Designed for smaller downlights and slim luminaires, they offer high efficiency and 100,000+ hour lifespans.

NFC Programming: Allows quick configuration of output current, DALI addresses, scene settings, and dimming curves using a smartphone or tool without powering the driver.

DALI-2 Certified: Ensures compatibility with standard DALI systems, supporting DT6 (single-channel) and sometimes DT8 (tunable white/colour).

Precise Constant Current: Delivers a stable current (e.g., 200–800mA or 350-1050mA) to protect LED longevity and provide consistent brightness.

Deep Dimming: Enables smooth, flicker-free dimming, often down to 0.01%–0.1%.

Advanced Features: Supports Constant Lumen Output (CLO), corridor functions, and comprehensive protection against overheating, short-circuit, and overloading.

Common Applications

  • Downlights and spotlights.
  • Decorative and emergency lighting.
  • Office lighting and smart building automation.

Typical Technical Specifications

Input Voltage: 220–240VAC or 100-240VAC.

Power Output: Typically 10W–60W.

Current Selection: 0.1mA increments via NFC.

Protection: IP20.

Tridonic are a Zumtobel Group company, founded in 1956 in Dornbirn, Austria. For more than 60 years, they have been a driving force in the development of professional lighting solutions.

Today, Tridonic is a world-leading provider of lighting technology for professional applications, including office buildings, and retail outlets, hotels and restaurants, the education industry and outdoor lighting sectors.

In Tridonics’ extensive range of energy-efficient dimmable and non-dimmable LED drivers they offer the right products for every indoor and outdoor application – from cost-efficient LED drivers in proven Tridonic quality to premium products that give you maximum flexibility and convenience.

Tridonics’ dimmable LED drivers can be controlled with different analog and digital dimming signals. Tridonic basicDIM Wireless products allow wireless control without additional wiring.

Need to know more about Tridonic 87500922 LC 27W 100-500mA 54V o4a NF SR – DALI 2 Certified?

You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.







    You may also be looking for...