28000666

Tridonic 22176409 PC 1Ă—57/70 TC PRO

22176409

SKU:22176409

Tridonic 22176409 PC 1Ă—57/70 TC PRO

The 22176409 is obsolete and out of stock, if you are operating the 1 x 57W TC-TEL lamp, the following can be used as a suitable alternative EL1/2X18-42TCS.

Tridonic HF ballast for 1 x 57W & 70W TC-TEL lamps.

£21.06
Ex.VAT
Inc.VAT£25.27

Less Than 10 Available!

Description

Tridonic 22176409 PC 1Ă—57/70 TC PRO

22176409 Key features

CELMA Energy Efficiency Index A2 BAT / A2
Nominal life-time up to 100,000 h (at ta 50 °C with a failure rate max. 0.2 % per 1,000 h)
Large temperature range (for values see table)
Devices can operate either 1 or 2 lamps
Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
Constant luminous flux irrespective of fluctuations in mains voltage
For luminaires of protection class I and protection class II
Automatic start after replacement of defective lamps
Safety shutdown of defective lamps and at end of lamp life (EOL 2)
For emergency lighting systems as per EN 50172
For luminaires with M and MM as per EN 60598, VDE 0710 and VDE 0711
Temperature protection as per EN 61347-2-3 C5e

https://resources.tridonic.com/PDB/Ressource/Web_TR/Archive_PDF/Ballasts_fluorescent_lamps/Fixed_output/DS_PC_TC_PRO_en.pdf

22176409 Common Data

22176409 Technical Data

Mains voltage range 220 – 240 V
AC voltage range 198 – 264 V
DC voltage range 176 – 280 V (Lamp start ≥ 198 V DC)
Mains frequency 0 / 50 / 60 Hz
Overvoltage protection 320 V AC, 1 h
Defined warm start ≤ 1.6 s
Operating frequency ≥ 40 kHz
Type of protection IP20

22176409 Standards

EN 55015
EN 60929
EN 61000-3-2
EN 61347-2-3
EN 61347-2-4
EN 61547
according to EN 50172

22176409 Lamp starting characteristics

Warm start
Starting time ≤ 1.6 s with AC and DC operation
Cathode heating will be reduced after preheat time

22176409 AC operation

Mains voltage:
220–240 V 50/60 Hz
198–264 V 50/60 Hz including safety
tolerance (±10 %)
202–254 V 50/60 Hz including performance
tolerance (+6 % / -8 %)

22176409 DC operation

220–240 V 0 Hz
198–280 V 0 Hz certain lamp start
176–280 V 0 Hz operating range
Light output level in DC operation: 100 %

22176409 Emergency lighting

Use in emergency lighting installations according to EN 50172 or for emergency luminaires according to EN 61347-2-3 appendix J.

Instant start after mains interruption < 0.5 s EBLF ≥ 0.5

Mains current for defective or missing lamps at DC operation < 10mA.

Intelligent Voltage Guard

Intelligent Voltage Guard is the name of an electronic monitor from Tridonic. This innovative feature of the PC PRO family of control gear from Tridonic immediately shows if the mains voltage rises above or falls below certain thresholds. Measures can then be taken quickly to prevent damage to the control gear.

• If the mains voltage rises above ≥ 306 V the lamps flash.
• This signal “demands” disconnection of the power supply to the lighting system.
• If the mains voltage falls below 150 V the control gear automatically disconnects the lamp circuit (light off) to protect the control gear from being irreparably damaged.

Smart heating

PC PRO with smart heating ignition technology optimises lamp start and ensures no energy is wasted. After the lamp has struck the filament heating is reduced automatically to a defined minimum value.

This reduction in filament heating, saves energy, yet maintains the proper operating conditions for the lamp. The lamp is always operated within specification.

PC PRO with X processor

The very latest in lighting management design technology. The lamp friendly warm start is delivering maximum lamp life and enables many frequency applications. Smallest power loss and new freedom in the lamp design thanks to convincing thermal management.

Energy class: CELMA EEI = A2 BAT / A21)

Maximum energy efficiency: Right from the early stages in the development of xitec technology the focus has always been on achieving maximum energy efficiency. In conjunction with Smart

Heating Technology, PC TC PRO is rated in the best possible efficiency class of A2 BAT that CELMA provides for ballasts with a constant luminous flux.

The ballast life duration is related to the ambient temperature ta. The relation of tc to ta temperature depends also on the luminaire design. If the measured tc temperature is approx. 5 K below tc max. or higher, ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request.

PC TC PRO is designed for an average life-time of 100,000 (at ta for ≥ 50.000 h) hours under reference conditions and with a failure probability of less than 10 %. This corresponds to an average failure rate of 0.2 % for every 1,000 hours of operation.

Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %)
Storage temperature: -40 °C up to max. +80 °C

The devices have to be within the specified temperature range (ta) before they can be operated.

22176409 Wiring advice

The lead length is dependant on the capacitance of the cable

22176409 Installation instructions

22176409 Wiring type and cross section

The wiring can be in stranded wires with ferrules or solid with a cross section of 0.5–1.5 mm². Strip 9.5 mm of insulation from the cables to ensure perfect operation of the push-wire terminals.

With standard solid wire 0.5/0.75mm² the capacitance of the lead is 30–80 pF/m. This value is influenced by the way the wiring is made. Lamp connection should be made with symmetrical wiring. Hot leads (10, 11, 16, 17) and cold leads (12, 13, 14, 15) should be separated as much as possible. When using two or more dimmable ballasts in one luminaire with separate dimming controls, the lamp leads must be kept separate.

22176409 RFI

Tridonic ballasts are RFI protected in accordance with EN 55015. To operate the luminaire correctly and and to minimise RFI we recommend the following instructions:

• Connection to the lamps of the “hot leads” must be kept as short as possible
• Mains leads should be kept apart from lamp leads
• Do not run mains leads adjacent to the electronic ballast
• Twist the lamp leads
• Keep the distance of lamp leads from the metal work as large as possible
• Connect functional earth to the ballast
• Keep the mains leads inside the luminaire as short as possible

Defective lamp

If a lamp is defective, the ballast switches off and goes into standby. Switch off tested according to EN 61347-2-3 17.3 (EoL-Test 2). There is an automatic restart once the lamp has been changed.

Insulation and electric strength testing of luminaires

Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production.

According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an insulation test with 500 V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal.

The insulation resistance must be at least 2MΩ.

As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted.

Glow-wire test

according to EN 61347-1 with increased temperature of 850 °C passed.

57W lamps are predominantly high-output, 4-pin compact fluorescent lamps (CFLs) designed for commercial, retail, and office environments, commonly featuring a GX24q-5 base and producing high lumen output (around 4300lm). They offer long lifespans (10,000–20,000 hours) and require external electronic ballasts, often used in downlights, hallways, and security lighting.

Key details about 57W lamps:

Base Type: GX24q-5 4-pin base (4-pin).

Colour Temperature: Available in various white tones, including 2700K (warm white), 3000K (warm white), and 4000K (cool white).

Brightness/Lumens: Approximately 4300 lumens, offering high light output for commercial applications.

Lifespan: Often last between 10,000 and 20,000 hours.

Usage: Frequently used in commercial spaces like offices, shops, and supermarkets for general and task lighting.

Ballast Requirement: These lamps require external high-frequency electronic ballast (HF) to operate.

70W 4-pin lamps, commonly CFL (Compact Fluorescent) or LED replacements, are high-output, energy-efficient lighting solutions used for commercial downlights, offices, and retail spaces. Typically featuring a GX24q-5 or GX24q-6 base, they produce roughly 5,200–5,400 lumens and last up to 20,000 hours, often featuring 3000K-4000K color temperatures.

Key Details for 70W 4-Pin CFL/LED Lamps:

Base Type: GX24q-5 or GX24q-6 (4-pin, plug-in).

Application: Ideal for high-ceiling commercial downlights, recessed lighting, and retail applications.

Performance: ~5200-5400 lumens (4-pin CFL).

Lifespan: Generally long-lasting, with many models offering 12,000 to 20,000 hours.

Ballast Requirement: 4-pin CFL bulbs require an electronic ballast to operate.

Colour Temperature: Commonly available in 3000K (Warm White) and 4000K (Cool White).

Alternatives: LED retrofits are available that can replace these 70W CFLs while offering increased energy savings and reduced heat output.

Tridonic are a Zumtobel Group company, founded in 1956 in Dornbirn, Austria. For more than 60 years, they have been a driving force in the development of professional lighting solutions.

Today, Tridonic is a world-leading provider of lighting technology for professional applications, including office buildings, and retail outlets, hotels and restaurants, the education industry and outdoor lighting sectors.

In Tridonics’ extensive range of energy-efficient dimmable and non-dimmable LED drivers they offer the right products for every indoor and outdoor application – from cost-efficient LED drivers in proven Tridonic quality to premium products that give you maximum flexibility and convenience.

Tridonics’ dimmable LED drivers can be controlled with different analog and digital dimming signals. Tridonic basicDIM Wireless products allow wireless control without additional wiring.

Need to know more about Tridonic 22176409 PC 1Ă—57/70 TC PRO?

You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.







    You may also be looking for...