Tridonic 28002412 LC 17/250-700/50 bDW SC PRE2 – DALI 2 Certified
28002412
Tridonic 28002412 LC 17/250-700/50 bDW SC PRE2
Can be integrated in Casambi systems (Casambi Ready)
NEW: lumDATA (Luminaire data, Energy reporting and Diagnostics & Maintenance)
Dimmable built-in constant current LED driver
Can be either used built-in or independent with clip-on strain-relief
£68.94
Ex.VAT Inc.VAT£82.73
Less Than 10 Available!
Description
Tridonic 28002412 LC 17/250-700/50 bDW SC PRE2
28002412 Description
Can be integrated in Casambi systems (Casambi Ready)
NEW: lumDATA (Luminaire data, Energy reporting and Diagnostics & Maintenance)
Dimmable built-in constant current LED driver
Can be either used built-in or independent with clip-on strain-relief; 28001168.
Forms automatically a wireless communication network with up to 250 nodes
Adjustable output current between 250 and 700 mA via I-SELECT 2 plugs
Max. output power 17 W
Up to 86 % efficiency
Power input on stand-by < 0.35 W
Dimming range 1 to 100 %
For luminaires of protection class I and protection class II
28002412 Housing properties
Casing: polycarbonate, white
Type of protection IP20
28002412 Interfaces
basicDIM Wireless
Terminal blocks: 45° push terminals
28002412 Functions
Adjustable output current in 1-mA-steps (I-SELECT 2)
Constant light output function (CLO)
Power-up fading at AC
Switch off the driver with fade2zero
Service monitor to log certain events
Protective features (overtemperature, short-circuit, overload, no-load, input voltage range, reduced surge amplification)
Intelligent Voltage Guard (overvoltage and undervoltage monitoring)
Suitable for emergency escape lighting systems acc. to EN 50172
28002412 Benefits
Application-oriented operating window for maximum compatibility
Best energy savings due to low stand-by losses and high efficiency
Flexible configuration via basicDIM Wireless and I-SELECT 2
Typical applications for the 28002412
For linear/area lighting in office applications
28002412 Common Data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
DC voltage range 176 – 280 V
Mains frequency 0 / 50 / 60 Hz
Overvoltage protection 320 V AC, 48 h
Typ. current (at 230 V, 50 Hz, full load) (1)(2) 65 – 95 mA
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) 15 – 25 mA
Leakage current (at 230 V, 50 Hz, full load) (1)(2) < 0.7 mA
Typ. input current in no-load operation 12.3 mA
In-rush current (peak / duration) 20 A / 140 µs
Max. input power 22.5 W
Typ. power consumption on stand-by < 0.35 W
Typ. input power in no-load operation 0.35 W
Typ. efficiency (at 230 V, 50 Hz, full load) (2) 86 %
λ (at 230 V, 50 Hz, full load) 0.96
THD (at 230 V, 50 Hz, full load) (1) < 3 %
Starting time (at 230 V, 50 Hz, full load) (3) < 0.7 s
Starting time (DC mode) (3) < 0.4 s
Switchover time (AC/DC) (4) < 0.4 s
Turn off time (at 230 V, 50 Hz, full load) < 0.03 s
Output current tolerance (1)(5) ± 3 %
Max. output current peak (non-repetitive) ≤ output current + 40 %
Output LF current ripple (< 120 Hz) ± 5 %
Output P_ST_LM (at full load) ≤ 1
Output SVM (at full load) ≤ 0.4
Max. output voltage (U-OUT) 60 V
Dimming range 1 – 100 %
Mains surge capability (between L – N) 1 kV
Mains surge capability (between L/N – PE) 2 kV
Surge voltage at output side (against PE) < 0.5 kV
Radio transceiver operation frequency 2.4 – 2.483 GHz
Max. output power radio transceiver (E.I. R.P.) (6) < + 20 dBm
Type of protection IP20
Length 130 mm
Width 43 mm
Height 30 mm
Lifetime up to 100000 h
28002412 Standards
EN 55015
EN 61000-3-2
EN 61000-3-3
EN 61347-1
EN 61347-2-13
EN 62384
EN 61547
ETSI EN 300 330
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 300 328
ETSI EN 301 489-17
According to EN 50172 for use in central battery systems
According to EN 60598-2-22 suitable for emergency lighting installations
Housing fulfils requirements for reinforced insulation according EN 60598-1.
28002412 Glow wire test
according to EN 61347-1 with increased temperature of 850 °C passed.
28002412 Thermal details and lifetime
The LED driver is designed for a lifetime stated above under reference conditions and with a failure probability of less than 10 %.
The relation of tc to ta temperature depends also on the luminaire design.
If the measured tc temperature is approx. 5 K below tc max., ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request.
28002412 Installation / wiring
Circuit diagram
28002412 Wiring type and cross section
For wiring use stranded wire with ferrules or solid wire from 0.2–1.5 mm². Strip 8.5–9.5 mm of insulation from the cables to ensure perfect operation of the push-wire terminals. Use one wire for each terminal connector only. Use each strain relief channel for one cable only.
28002412 Fixing conditions when using as independent Driver with Clip-On
Dry, acidfree, oilfree, fatfree. It is not allowed to exceed the maximum ambient temperature (ta) stated on the device. Minimum distances stated below are recommendations and depend on the actual luminaire. Device is not suitable for fixing in corner.
28002412 Wiring guidelines
• Run the secondary lines separately from the mains connections and lines to achieve good EMC performance.
• The max. secondary cable (LED module) length is 2 m (4 m circuit).
• For good EMC performance, keep the LED wiring as short as possible.
• To comply with the EMC regulations run the secondary wires (LED module) in parallel.
• Secondary switching is not permitted.
• The LED driver has no inverse-polarity protection on the secondary side. Wrong polarity can damage LED modules with no inverse-polarity protection.
• Wrong wiring of the LED driver can lead to malfunction or irreparable damage.
• To avoid damage of the Driver, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.).
28002412 Hot plug-in
Hot plug-in is not supported due to residual output voltage of > 0 V. When connecting an LED load, restart the device to activate the LED output. This can be done via mains reset or interface (basicDIM Wireless).
28002412 Earth connection
The earth connection is conducted as protection earth (PE). The LED driver can be earthed via earth terminal. If the LED driver will be earthed, protection earth (PE) has to be used. There is no earth connection required for the functionality of the LED driver. Earth connection is recommended to improve following behaviour:
• Electromagnetic interferences (EMI)
• LED glowing at standby
• Transmission of mains transients to the LED output
In general it is recommended to earth the LED driver if the LED module is mounted on earthed luminaire parts respectively heat sinks and thereby representing a high capacity against earth.
28002412 Installation note
Max. torque at the clamping screw: 0.5 Nm / M4
Electrical values
Operating window
Make sure that the LED driver is operated within the given window under all operating conditions. Special attention needs to be paid at dimming and DC emergency operation as the forward voltage of the connected LED modules varies with the dimming level, due to the implemented amplitude dimming technology. Coming below the specified minimum output voltage of the LED driver may cause the device to shut-down. See chapter “6.9 Light level in DC operation” for more information.
Maximum loading of automatic circuit breakers in relation to inrush current
These are max. values calculated out of inrush current! Please consider not to exceed the maximum rated continuous current of the circuit breaker. Calculation uses typical values from ABB series S200 as a reference. Actual values may differ due to used circuit breaker types and installation environment.
Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in %
Acc. to 61000-3-2. Harmonics < 5 mA or < 0.6 % (whatever is greater) of the input current are not considered for calculation of THD.
Dimming
Dimming range 1 % to 100 %
Digital control with:
• basicDIM Wireless
28002412 Interfaces / communication
Control input
A standard push button can be connected on the input terminals. Maximum cable length of the push button is 1 meter. This function have to be activated before using. The control signal is not SELV. Control cable has to be installed in accordance to the requirements of low voltage installations. Different functions depending on each module.
28002412 Functions
Function: adjustable current
The output current of the LED driver can be adjusted in a certain range. For adjustment there is one option available.
Option 1: I-SELECT 2
By inserting a suitable resistor into the I-SELECT 2 interface, the current value can be adjusted. The relationship between output current and resistor value can be found in the chapter “Accessories I-SELECT 2 Plugs”.
Short-circuit behaviour
In case of a short-circuit at the LED output the LED output is switched off. After restart of the LED driver the output will be activated again. The restart can either be done via mains reset or via software or pushBUTTON.
No-load operation
The LED driver will not be damaged in no-load operation. The output will be deactivated and is therefore free of voltage. If a LED load is connected the device has to be restarted before the output will be activated again.
Overload protection
If the maximum load is exceeded by a defined internal limit, the LED driver turns off the LED output. After restart of the LED driver the output will be activated again.
The restart can either be done via mains reset or via software or pushBUTTON.
Overtemperature protection
The LED driver is protected against temporary thermal overheating. If the temperature limit is exceeded the output current of the LED module(s) is reduced. The temperature protection is activated above tc max.
The activation temperature differs depending on the LED load. On DC operation this function is deactivated to fulfill emergency requirements.
OEM Identification
The OEM (Original Equipment Manufacturer) can set his own identification number.
OEM GTIN
The Original Equipment Manufacturer (OEM) can set his own Global Trade Item Number (GTIN).
Luminaire data
This function provides the asset management with accurate data about the luminaire.
Constant light output (CLO)
The luminous flux of a LED decreases constantly over the lifetime. The CLO function ensures that the emitted luminous flux remains stable. For that purpose the LED current will increase continuously over the LED lifetime. The LED driver adjusts the current afterwards automatically.
Power-up/-down fading
The power-up/-down function offers the opportunity to modify the on-/off behavior. The time for fading on or off can be adjusted in a range of 0.2 to 16 seconds. According to this value, the device dims either from 0 % up to the power-on level or from the current set dim level down to 0 %.
This feature applies while operating via 4remoteBT and when switching the mains voltage on or off. By factory default no fading time is set (=0s).
fade2zero
When the Driver is switched off, fade2zero allows a smooth dimming down to almost zero. fade2zero only works if the minimum dimming level of the Driver is the default value.
The device then dims to far below the limit of its working window (dimming range). This function is deactivated by default.
Light level in DC operation
The LED driver is designed to operate on DC voltage and pulsed DC voltage. For a reliable operation, make sure that also in DC emergency operation the LED driver is run within the specified conditions as stated in chapter “4.1 operating window”.
Light output level in DC operation: programmable 1 – 100 % (EOFi = 0.13). The voltage-dependent input current of Driver incl. LED module is depending on the used load. The voltage-dependent no-load current of Driver (without or defect LED module) is for:
AC: < 12.2 mA
DC: < 1.3 mA
28002412 Intelligent Voltage Guard
Intelligent Voltage Guard is the name of the electronic monitoring of the mains voltage. It immediately shows if the mains voltage rises above certain thresholds. Measures can then be taken quickly to prevent damage to the LED driver.
• If the mains voltage rises above approx. 280 Vrms (voltage depends on the LED driver type), the LED light starts flashing on and off.
• To avoid a damage of the LED driver the mains supply has to be switched off at this signal.
28002412 Software / programming
With appropriate software and an interface different functions can be activated and various parameters can be configured in the LED driver. To do so, the utilityAPP is required.
Miscellaneous
Insulation and electric strength testing of luminaires
Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an insulation test with 500V DC for 1 second. This test voltage should be connected between the interconnected
phase and neutral terminals and the earth terminal.
The insulation resistance must be at least 2MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500V AC (or 1.414 x 1500V DC). To avoid damage to the electronic devices this test must not be conducted.
Conditions of use and storage
Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %)
Storage temperature: -40 °C up to max. +80 °C
The devices have to be acclimatised to the specified temperature range (ta) before they can be operated.
The LED driver is declared as inbuilt LED controlgear, meaning it is intended to be used within a luminaire enclosure.
If the product is used outside a luminaire, the installation must provide suitable protection for people and environment (e.g. in illuminated ceilings).
Placement
basicDIM Wireless has an integrated antenna for easy integration. In order to maximize the range in every direction some design guidelines should be taken into consideration when mounting the device.
The antenna is located on the corner of the enclosure. It is on the top side of the internal PCB (Printed Circuit Board).
When the device is mounted on a metal plate (e.g. frame of a luminaire), it may efficiently block the radio frequency signal. In this case, a cut-out underneath the antenna may be needed for the RF signal to exit the structure.
The cut-out area should be as large as possible. Also the device should be placed as far away from any vertical metal structures as possible.
Network compatibility
This Driver is fully compatible with networks which support up to 250 nodes (Evolution networks). If the Driver is used with different types of basicDIM
Wireless devices in an Evolution network, their compatibility has to be checked before. If a device is not compatible with Evolution networks, it can be only used in networks which support up to max. of 127 devices (Classic networks).
Maximum number of switching cycles
All LED driver are tested with 50,000 switching cycles. The actually achieved number of switching cycles is significantly higher.
Tridonic are a Zumtobel Group company, founded in 1956 in Dornbirn, Austria. For more than 60 years, they have been a driving force in the development of professional lighting solutions.
Today, Tridonic is a world-leading provider of lighting technology for professional applications, including office buildings, and retail outlets, hotels and restaurants, the education industry and outdoor lighting sectors.
In Tridonics’ extensive range of energy-efficient dimmable and non-dimmable LED drivers they offer the right products for every indoor and outdoor application – from cost-efficient LED drivers in proven Tridonic quality to premium products that give you maximum flexibility and convenience.
Tridonics’ dimmable LED drivers can be controlled with different analog and digital dimming signals. Tridonic basicDIM Wireless products allow wireless control without additional wiring.
Need to know more about Tridonic 28002412 LC 17/250-700/50 bDW SC PRE2 – DALI 2 Certified?
You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.