Tridonic 89800562 EM converterLED BASIC 204 NiCd/NiMH 90V
89800562
Tridonic 89800562 EM converterLED BASIC 204 NiCd/NiMH 90V
Emergency lighting LED driver for manual testing
For self-contained emergency lighting
For LED modules with a forward voltage of 40–97 V
SELV for output voltage < 120 V DC
Low profile casing (21 x 30 mm cross-section)
For luminaire installation
£27.39
Ex.VAT Inc.VAT£32.87
Less Than 10 Available!
Description
Tridonic 89800562 EM converterLED BASIC 204 NiCd/NiMH 90V
Emergency lighting LED driver for manual testing
For self-contained emergency lighting
For LED modules with a forward voltage of 40-97 V
SELV for output voltage < 120 V DC
Low profile casing (21 x 30 mm cross-section)
For luminaire installation
Nominal lifetime up to 100,000 h
89800562 Properties
Non maintained operation
1 or 3 h rated duration
Operating time selectable with plug (duration link)
Compatible with all dimmable and non-dimmable constant current LED driver (see data sheet, LED driver compatibility)
3-pole technology: 2-pole LED module changeover and delayed power switching for the LED driver
Automatic shutdown of output if LED load is out of range
Constant power output
Maximum light output for all LED modules
Electronic charge system
Deep discharge protection
Short-circuit-proof battery connection
Polarity reversal protection for battery
Batteries
High-temperature cells
NiCd or NiMH batteries
D, Cs or LA cells
4 year design life
See our; 4DH4-0L4 & B904for suitability
89800562 Common Data
Rated supply voltage 220 – 240 V
AC voltage range 198 – 264 V
Forward voltage range LED module 40 – 97 V
Mains frequency 50 / 60 Hz
Overvoltage protection 320 V (for 48 h)
Output current Refer to data sheet
Typ. λ (at 230 V, 50 Hz) 0.6 C
Starting time < 0.25 s from detection of emergency event
U-OUT (including open- / short-circuit and double load) 120 V
Max. open circuit voltage 120.0 V
Mains voltage changeover threshold According to EN 60598-2-22
Mains surge capability (between L – N) 1 kV
Mains surge capability (between L/N – PE) 2 kV
Battery charging time (1)(2) 24 h
Ambient temperature ta -5 – 55 °C
Max. casing temperature tc 75 °C
Type of protection IP20
Lifetime up to 100000 h
Other information for the 89800562
89800562 Standards
• EN 61347-1
• EN 61347-2-13
• EN 61347-2-7
• EN 55015
• EN 61000-3-2
• EN 61000-3-3
• EN 61547
• EN 60068-2-64
• EN 60068-2-29
• EN 60068-2-30
• EN 62384
• according to EN 50172
• according to EN 60598-2-22
Double or reinforced insulation for built-in electronic LED drivers. The control gear relies upon the luminaire enclosure for protection against accidental contact with live parts.
Glow-wire test
According to EN 61347-1 with increased temperature of 850 °C passed.
Insulation and electric strength testing of luminaires
Electronic LED-drivers can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production.
According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an insulation test with 500VDC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The insulation resistance must beat least 2 MΩ.
As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1,500VAC (or 1,414 x 1,500VDC). To avoid damage to the electronic devices this test must not be conducted.
89800562 Thermal details and lifetime
89800562 Lifetime
Average lifetime 50,000 hours under rated conditions with a failure rate of less than 10 %. Average failure rate of 0.2 % per 1000 operating hours
The emergency lighting LED driver is designed for a lifetime stated above under reference conditions and with a failure probability of less than 10 %.
The relation of tc to ta temperature depends also on the luminaire design.
If the measured tc temperature is approx. 5 K below tc max., ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request.
89800562 Wiring
• The output to the LED is DC but has high frequency content, which should be considered for good EMC compliance.
• Separate LED leads from the mains and DALI connections and wiring for good EMC performance.
• Maximum lead length on the LED terminals is 3 m. For a good EMC performance keep the LED wiring as short as possible.
• Route the secondary wires (LED module) in parallel to ensure good EMC performance.
• Maximum lead length for the Test switch and Indicator LED connection is 1 m. Separate the test switch and Indicator LED wiring from the LED leads to prevent noise coupling.
• Battery leads are specified with 0.5 mm cross section and a length of 0.8 m
• DALI terminals are mains proof.
• Protect the wiring against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.) to avoid the damage of the control gear.
To ensure that a luminaire containing LED emergency units complies with EN 55015 for radio frequency conducted interference in both normal and emergency mode it is essential to follow good practice in the wiring layout.
Within the luminaire route the switched and unswitched 50Hz supply wiring as short as possible and keep it as far away as possible from the LED leads.Through wiring may affect the EMC performance of the luminaire.
Do not exceed the max. length of LED leads to the LED module.
Note that the length of the EM converterLED leads to the LED module is added to the length of the leads from the LED driver to the EM converterLED module when considering the max. permitted lead length of the LED driver.
89800562 Maximum lead length
LED 3 m (1)Note
Status indication LED 1 m
Batteries 1 m
(1)Note: The length of LED leads to the LED module must not be exceeded. Note that the length of the EM converterLED leads is added to the length of the leads from the LED driver to the EM converterLED module when considering max. permitted lead length of the LED driver. Leads
should always be kept as short as possible.
89800562 Mechanical values
Housing properties
• Casing manufactured from polycarbonate.
• Type of protection: IP20
• Max. torque at the mounting screws: 0.8 Nm
89800562 Mechanical data accessories
LED status indicator
• Green
• Mounting hole 6.5 mm diameter, 1 – 1.6 thickness
• Lead length 0.3 m / 0.6 m / 1.0 m
• Insulation rating: 90 °C
• Plug connection
Test switch
• Mounting hole 7.0 mm diameter
• Lead length 0.55 m
• Plug connection
Battery leads
• Quantity: 1 red and 1 black
• Length: 1.3 m
• Wire type: 0.5 mm2 solid conductor
• Insulation rating: 90 °C
Battery end termination
Push on 4.8 mm receptacle to suit battery spade fitted with insulating cover
Module end termination
8.0 mm stripped insulation
Two-piece batteries are supplied with a 200 mm lead with 4.8 mm receptacle at each end and insulting covers to connect the separate sticks together.
Typ. LED current/voltage characteristics
The LED current in emergency mode is automatically adjusted by the EM converterLED module based on the total forward voltage of the LED modules connected and the associated battery.
The start of the LED in emergency mode does not result in a current peak.
LED driver compatibility
The EM converterLED emergency unit use 3 pole technology and is compatible with most LED drivers on the market, however it is important to check that the rating of the LED driver does not exceed the values specified below:
• The max. allowed output current rating of the associated LED driver is 2 A eff (current rating of the terminals of EM converterLED) and 2.4 A peak (current rating of switching relays of EM converterLED)
• The max. allowed inrush current rating of the associated LED driver is 60 A peak for 1 ms or 84 A for 255 μs (inrush current rating of switching
relay of EM converterLED)
• The max. allowed output voltage (U-OUT) of the associated LED driver applied to the EM converterLED output is 450 V (voltage withstand between adjacent contact of the single switching relay of the EM converterLED)
• The max. allowed LED load of the associated LED driver is 150 W in operation. The load must be an LED module.
89800562 Functions
Emergency lighting LED driver supplied with duration link in 3 hours position.
The position of the link will only be read on first power up. If it is changed afterwards both the battery and mains supply must be disconnected for 10 seconds to enable the EM converterLED to read the new link position on reconnection of the battery and mains. It will lead to a false battery failure indication if the link is changed after installation without this reset.
Status indication LED
System status is indicated by a green LED.
Note:
The status indication LED switches off if the battery does not reach the full capacity (3.6V battery voltage) within 20 – 24 hours.
If this occurs disconnect the mains voltage and operate the device in emergency mode for approximately one hour. Afterwards apply the mains voltage again and recharge the battery for 24 hours.
If the failure occurs again replace the battery.
Tridonic are a Zumtobel Group company, founded in 1956 in Dornbirn, Austria. For more than 60 years, they have been a driving force in the development of professional lighting solutions.
Today, Tridonic is a world-leading provider of lighting technology for professional applications, including office buildings, and retail outlets, hotels and restaurants, the education industry and outdoor lighting sectors.
In Tridonics’ extensive range of energy-efficient dimmable and non-dimmable LED drivers they offer the right products for every indoor and outdoor application – from cost-efficient LED drivers in proven Tridonic quality to premium products that give you maximum flexibility and convenience.
Tridonics’ dimmable LED drivers can be controlled with different analog and digital dimming signals. Tridonic basicDIM Wireless products allow wireless control without additional wiring.
Need to know more about Tridonic 89800562 EM converterLED BASIC 204 NiCd/NiMH 90V?
You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.