Tridonic 89800602 EMpowerLED BASIC FX 234 LP 75W 220V – Combined Emergency Lighting LED Driver
89800602
Tridonic 89800602 EMpowerLED BASIC FX 234 LP 75W 220V
89800602 description
Fixed output LED driver for mains operation
Emergency lighting LED driver with manual test function
For self-contained emergency lighting
For LED modules with a forward voltage of 50 – 220 V
£63.33
Ex.VAT Inc.VAT£76.00
Description
Tridonic 89800602 EMpowerLED BASIC FX 234 LP 75W 220V
89800602 description
Fixed output LED driver for mains operation
Emergency lighting LED driver with manual test function
For self-contained emergency lighting
For LED modules with a forward voltage of 50 – 220 V
For luminaire installation
Low profile cross-section (21 x 30 mm)
EM = Emergency
89800602 Properties
6 – 75 W output power
Constant current LED operation
Adjustable output current between 100 and 400 mA via ready2mains Programmer or I-SELECT 2 plugs
Integrated emergency lighting unit
1 or 3 h rated duration
Automatic shutdown of output if LED load is out of range
Green charge status display LED
Electronic charge system
Polarity reversal protection for battery
Deep discharge protection
Short-circuit-proof battery connection
89800602 Batteries
High-temperature cells
NiCd (4DH4-0L4) or NiMH (B904) batteries
D, Cs or LAL cells
4 year design life
For battery compatibility refer to data sheet, battery selection
89800602 Common Data
Rated supply voltage AC 220 – 240 V
AC voltage range 198 – 264 V
Mains frequency 50 / 60 Hz
Typ. rated current (at 230 V, 50 Hz, full load) 1 380 mA
Leakage current (at 230 V, 50 Hz, full load) 1 < 250 µA
Max. input power 85 W
Typ. λ (at 230 V, 50 Hz, normal operation) 0.98
Overvoltage protection 320 V (for 48 h)
Battery charging time < 24 h
U-OUT (including open- / short-circuit and double load) 280 V
Typ. input current in no-load operation 1 hr (charging) 16 mA
Typ. input current in no-load operation 3 hr (charging) 18 mA
Typ. input power in no-load operation 1 hr (charging) 2 W
Typ. input power in no-load operation 3 hr (charging) 2.4 W
In-rush current (peak / duration) 26 A / 280 µs
THD (at 230 V, 50 Hz, full load) 1 < 10 %
Starting time < 0.5 s from detection of emergency event
Starting time (mains off) < 1.3 s
Starting time (stand-by) < 250 ms
Turn off time (at 230 V, 50 Hz, full load) < 50 ms
Output LF current ripple (< 120 Hz) < 5 %
Output current tolerance 5 %
Ambient temperature ta -5 … +50 °C
Max. casing temperature tc 75 °C
Mains surge capability (between L – N) 1 kV
Mains surge capability (between L/N – PE) 2 kV
Surge voltage at output side (against PE) 2 kV
Dimensions L x W x H 360 x 30 x 21 mm
Mains voltage changeover threshold According to EN 60598-2-22
Type of protection IP20
Lifetime up to 50,000 h
89800602 Standards
• EN 61347-1
• EN 61347-2-13
• EN 61347-2-7
• EN 62384
• EN 55015
• EN 61547
• EN 61000-3-2
• EN 60068-2-29
• EN 60068-2-30
• EN 60068-2-64
• according to EN 50172
• according to EN 60598-2-22
89800602 Thermal data
89800602 Expected Lifetime
Average lifetime 50,000 hours under rated conditions with a failure rate of less than 10 %. Average failure rate of 0.2 % per 1000 operating hours.
The EM powerLED is designed for a lifetime stated above under reference conditions and with a failure probability of less than 10 %. The relation of tc to ta temperature depends also on the luminaire design.
If the measured tc temperature is approx. 5 K below tc max., ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request.
89800602 Installation / Wiring
89800602 Wiring diagrams
The connected LED module will be used for mains and emergency operation. The mains power must be removed before changing the LED load.
Secondary switching of LEDs is not allowed and may cause damage to the LEDs. The hot plug-in of LEDs during normal operation may result in high current peaks.
89800602 Wiring type and cross section
Solid wire with a cross section of 0.5 – 1.5 mm². Strip 8 – 9 mm of insulation from the cables to ensure perfect operation of terminals.
89800602 Wiring guidelines
• The output to the LED is DC but has high frequency content, which should be considered for good EMC compliance.
• LED leads should be separated from the mains connections and wiring for good EMC performance.
• Maximum lead length on the LED terminals is 3 m. For a good EMC performance keep the LED wiring as short as possible.
• The secondary wires (LED module) should be routed in parallel to ensure good EMC performance.
• Maximum lead length for the Test switch and Indicator LED connection is 1 m. The test switch and Indicator LED wiring should be separated from the LED leads to prevent noise coupling.
• Battery leads are specified with 0.5 mm cross section and a length of 1.3 m.
• To avoid the damage of the control gear, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.). To ensure that a luminaire containing LED emergency units complies with
EN 55015 for radio frequency conducted interference in both normal and emergency mode it is essential to follow good practice in the wiring layout. Within the luminaire the switched and unswitched 50Hz supply wiring must be routed as short as possible and be kept as far away as possible from the LED leads.
Through wiring may affect the emc performance of the luminaire. The length of LED leads must not be exceeded. The output current depends on the forward voltage and the tolerance of the
LED modules.
89800602 Mechanical data
89800602 Housing properties
• Low-profile metal casing with white cover
• Type of protection IP 20
Mechanichal data accessories
LED status indicator
• Green
• Mounting hole 6.5 mm diameter, 1 – 1.6 mm thickness
• Lead length 0.8 m
• Insulation rating: 90 °C
Test switch
• Mounting hole 7.0 mm diameter
• Lead length 0.55 m
Battery leads
• Quantity: 1 red and 1 black
• Length: 1.3 m
• Wire type: 0.5 mm2 solid conductor
• Insulation rating: 90 °C
Battery end termination
Push on 4.8 mm receptacle to suit battery spade fitted with insulating cover or plug connection.
Module end termination
8.0 mm stripped insulation
Two-piece batteries are supplied with a 200 mm lead with 4.8 mm receptacle at each end and insulating covers to connect the separate sticks together.
89800602 Functions
Function: adjustable current
The output current of the EM powerLED can be adjusted in a certain range. For adjustment there are two options available.
Option 1: I-select 2
By inserting a suitable resistor or third party resistor into the I-select 2 interface, the current value can be adjusted. The relationship between output current and resistor value can be found in the chapter “Accessories I-SELECT 2 Plugs”.
Please note that the resistor values for I-select 2 are not compatible with I-select (generation 1). Installation of an incorrect resistor may cause irreparable damage to the LED module(s).
Resistors for the main output current values can be ordered from Tridonic (see accessories).
Option 2: ready2mains
Adjustment is done by the ready2mains Programmer and the corresponding configuration software (see ready2mains documentation).
Current adjustment can only be done five times over ready2mains. To program the EM powerLED a connected load is necessary that is within the operating window of the EM powerLED.
The priority for current adjustment methods is I-select 2 followed by ready2mains (lowest priority).
Short-circuit behaviour
In case of a short-circuit at the LED output the LED output is switched off. After restart of the EM powerLED the output will be activated again. The restart can either be done via mains reset or via interface ready2mains.
No-load operation
The EM powerLED will not be damaged in no-load operation. The output will be deactivated and is therefore free of voltage. If a LED load is connected the device has to be restarted before the output will be activated again.
Overload protection
If the output voltage range is exceeded the EM powerLED turns off the LED output. After restart of the EM powerLED the output will be activated again. The restart can be done via mains reset.
Overtemperature protection
The EM powerLED is protected against temporary thermal overheating. If the temperature limit is exceeded the output current of the LED module(s) is reduced. The temperature protection is activated approx. +5 °C above tc max
Forward voltage out of range
If the forward voltage is out of range the unit switches to shut down mode. After elimination of the short circuit a mains reset (SL off/on) is necessary
Miscellaneous
Maximum number of switching cycles
All LED Drivers are tested with 50,000 switching cycles. The actually achieved number of switching cycles is significantly higher.
Insulation and electric strength testing of luminaires
Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production.
According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an insulation test with 500V DC for one
second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal.
The insulation resistance must be at least 2MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500V AC (or 1.414 x 1500V DC). To avoid damage to the electronic devices this test must not be conducted.
Conditions of use and storage
Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %)
Storage temperature: -40 °C up to max. +80 °C
The devices have to be acclimatised to the specified temperature range (ta) before they can be operated.
Tridonic are a Zumtobel Group company, founded in 1956 in Dornbirn, Austria. For more than 60 years, they have been a driving force in the development of professional lighting solutions.
Today, Tridonic is a world-leading provider of lighting technology for professional applications, including office buildings, and retail outlets, hotels and restaurants, the education industry and outdoor lighting sectors.
In Tridonics’ extensive range of energy-efficient dimmable and non-dimmable LED drivers they offer the right products for every indoor and outdoor application – from cost-efficient LED drivers in proven Tridonic quality to premium products that give you maximum flexibility and convenience.
Tridonics’ dimmable LED drivers can be controlled with different analog and digital dimming signals. Tridonic basicDIM Wireless products allow wireless control without additional wiring.
Need to know more about Tridonic 89800602 EMpowerLED BASIC FX 234 LP 75W 220V – Combined Emergency Lighting LED Driver?
You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.