The Philips Advance PureVOLT IUV-2S60-M4-LD is a versatile, electronic, programmed-start ballast designed for UV-C germicidal lamps (35W–145W, including T5HO and PL-L). It features 120-277V IntelliVolt technology, lamp EOL protection, and supports 1 or 2-lamp series operation.

£74.63
Ex.VAT
Inc.VAT£89.56

Less Than 10 Available!

Quantity Price (each)
1 £74.63
5 £73.36
10+ £72.02

Description

PureVolt IUV-2S60-M4-LD

The Philips Advance PureVOLT IUV-2S60-M4-LD is a versatile, electronic, programmed-start ballast designed for UV-C germicidal lamps (35W–145W, including T5HO and PL-L). It features 120-277V IntelliVolt technology, lamp EOL protection, and supports 1 or 2-lamp series operation.

Key Features & Technical Specifications of the IUV-2S60-M4-LD

Manufacturer: Signify (Philips)
Type: Microprocessor-controlled electronic ballast
Voltage: Universal Input Voltage (120-277V, 50/60 Hz)
Lamp Compatibility: Optimized for Philips germicidal lamps, including 55W HO, 75W HO, 35W/60W/95W PL-L (Twin Tube), and 36T5HO/64T5HO
Wiring: Series connection
Features: End-of-Lamp (EOL) protection, Programmed Start, and IntelliVolt
Dimensions:L198 mm x W 76mm x H 33 mm
Common Applications: Used in Germicidal UV-C systems for water and air purification, including sterilization applications.

https://www.signify.com/en-gb

IUV-2S60-M4-LD Common Data

IUV-2S60-M4-LD Technical Data

Part Number IUV-2S60-M4-LD
Brand Name PUREVOLT
Ballast Type Electronic
Starting Method Programmed Start
Lamp Connection Series
Input Voltage 120-277
Input Frequency 50/60 HZ
Status Active

IUV-2S60-M4-LD Wiring Diagram

IUV-2S60-M4-LD Dimensions

L198 mm x W 76mm x H 33 mm

IUV-2S60-M4-LD Electrical Specifications at 120V

Section I – Physical Characteristics

1.1 Ballast shall be physically interchangeable with standard electromagnetic or standard electronic ballasts, where applicable.
1.2 Ballast shall be provided with integral leads color-coded per ANSI C82.11.

Section II – Performance

2.1 Ballast shall be Programmed Start.
2.2 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power
2.3 Ballast shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/- 10% (voltage and frequency).
2.4 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared devices and eliminate visible flicker.
2.5 Ballast shall have a Power Factor greater than 0.96 for primary lamp.

2.6 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less.
2.7 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp.
2.8 Ballast shall have a Class A sound rating.
2.9 Ballast shall have a minimum starting temperature of -18C (-0F) for primary lamp.
2.10 Ballast shall provide Lamp EOL Protection Circuit
2.11 Ballast shall tolerate sustained open circuit and short circuit output conditions.

Section III – Regulatory

3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified where applicable.
3.3 Ballast shall be rated for use in air-handling spaces.
3.4 Ballast shall comply with ANSI C62.41 Category A for Transient protection.

3.5 Ballast shall comply with ANSI C82.11 where applicable.
3.6 Ballast shall comply with applicable requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18, for Non-Consumer equipment.
3.6 Ballast shall comply with NEMA 410 for in-rush current limits.
3.7 Ballast shall meet RoHS Compliance Standards

Section IV – Other

4.1 Ballast shall be manufactured in a factory certified to ISO 9001 Quality System Standards.
4.2 Ballast shall carry a ____ year warranty from date of manufacture against defects in material or workmanship, including replacement, for operation at a maximum case temperature of ___C. (Go to our web site for up-to-date warranty information: www.philips.com/advancewarranty)
4.3 Manufacturer shall have a twenty-year history of producing electronic ballasts for the North American market

IUV-2S60-M4-LD Electrical Specifications at 277V

Section II – Performance

2.1 Ballast shall be Programmed Start.
2.2 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power
2.3 Ballast shall operate from 50/60 Hz input source of 120V through 277V with sustained variations of +/- 10% (voltage and frequency).
2.4 Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared devices and eliminate visible flicker.
2.5 Ballast shall have a Power Factor greater than 0.96 for primary lamp.

2.6 Ballast shall provide for a Lamp Current Crest Factor of 1.7 or less.
2.7 Ballast input current shall have Total Harmonic Distortion (THD) of less than 10% when operated at nominal line voltage with primary lamp.
2.8 Ballast shall have a Class A sound rating.
2.9 Ballast shall have a minimum starting temperature of -18C (-0F) for primary lamp.
2.10 Ballast shall provide Lamp EOL Protection Circuit
2.11 Ballast shall tolerate sustained open circuit and short circuit output conditions.

Section III – Regulatory

3.1 Ballast shall not contain any Polychlorinated Biphenyl (PCB).
3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P and Type 1 Outdoor; and Canadian Standards Association (CSA) certified where applicable.
3.3 Ballast shall be rated for use in air-handling spaces.
3.4 Ballast shall comply with ANSI C62.41 Category A for Transient protection.

3.5 Ballast shall comply with ANSI C82.11 where applicable.
3.6 Ballast shall comply with applicable requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR part 18,
for Non-Consumer equipment.
3.6 Ballast shall comply with NEMA 410 for in-rush current limits.
3.7 Ballast shall meet RoHS Compliance Standards

Section IV – Other

4.1 Ballast shall be manufactured in a factory certified to ISO 9001 Quality System Standards.
4.2 Ballast shall carry a ____ year warranty from date of manufacture against defects in material or workmanship, including replacement, for operation
at a maximum case temperature of ___C. (Go to our web site for up-to-date warranty information: www.philips.com/advancewarranty)
4.3 Manufacturer shall have a twenty-year history of producing electronic ballasts for the North American market.

UV-C germicidal ballasts are critical electrical devices that regulate voltage and current for mercury, amalgam, or fluorescent UV-C lamps, preventing burnout and ensuring consistent, maximum germicidal output. They serve to start, power, and maintain the lamp’s arc, often converting 120VAC/240VAC or 12/24VDC to high-voltage (>400V) outputs for sterilization systems. These electronic ballasts maximize lamp life and are essential for HVAC air, water purification, and surface disinfection systems.

Key Functions and Characteristics

Current Regulation: Because UV-C lamps have negative resistance, the ballast restricts current flow to prevent premature failure.

Starting and Operation: Ballasts provide high starting voltage to light the lamp, then switch to a lower, stable operating voltage.

High Efficiency: Modern electronic ballasts are more efficient, smaller, and lighter than traditional magnetic options, often featuring soft-start functionality to protect cathodes.

Amalgam Compatibility: Specialized ballasts are required to run amalgam lamps, which produce three times more UVC output than standard lamps.

Longevity: UV ballasts typically last 3 to 5 years, with high-end models lasting up to 10 years.

Key Considerations for Selection

Lamp Type & Current: Matching the ballast to the lamp’s required operating current (e.g., 425mA, 800mA, or >1200mA for amalgam) is vital.

Input Power: Options include 120VAC, 240VAC, 24VAC (common in HVAC), and 12VDC/24VDC for portable devices.

Start Method: Rapid start or programmed (soft) start options are available, with soft start preferred for high-cycling applications to prolong bulb life.

Philips is one of the world’s most trusted lighting brands. Since 1891, Philips has been synonymous with high-quality, reliable, innovative technology that improve people’s lives.
The Philips brand is licensed to Signify, world leader in lighting, for lighting products and services. Philips is Signify’s primary brand for lamps, luminaires, and other lighting products for both professionals and consumers.

Signify products carrying the Philips brand cover the complete range of lighting applications, from home, office, and industry to street lighting, horticulture, sports, and more.

Signify is the world leader in lighting. They provide professional customers and consumers with quality products, systems and services. And their connected lighting offerings bring light and the data they collect to devices, places and people – redefining what light can do and how people use it. Their innovations contribute to a safer, smarter more sustainable world.

Signify is the world leader in lighting for professionals, consumers and lighting for the Internet of Things. Their energy efficient lighting products, systems and services enable their customers to enjoy a superior quality of light, and make people’s lives safer and more comfortable, businesses more productive and cities more liveable.

With 2024 sales of EUR 6.1 billion, approximately 29,000 employees and a presence in over 70 countries, they are unlocking the extraordinary potential of light for brighter lives and a better world.

Need to know more about PureVolt IUV-2S60-M4-LD – IntelliVolt Technology & Lamp EOL Protection?

You can email us at: sales@ledparts.co.uk or alternatively you can request a callback by completing the form below and we'll get back to you as soon as possible.







    You may also be looking for...